中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Automated on-line liquid chromatography-photodiode array-mass spectrometr method with dilution line for the determination of bisphenol A and 4-octylphenol in serum

文献类型:期刊论文

作者Liu, Min; Hashi, Yuki; Pan, Fengyun; Yao, Jianguo; Song, Guanqun; Lin, Jin-Ming
刊名JOURNAL OF CHROMATOGRAPHY A
出版日期2006
卷号1133期号:2015-01-02页码:142-148
关键词on-line LC-DAD-MS dilution line bisphenol A 4-octyphenol
英文摘要A novel on-line liquid chromatography-photodiode array detection-mass spectrometry (LC-DAD-MS) system was established with restricted-access media (RAM) pre-column and dilution line combined with a column-switching valve. The serum samples were injected directly onto pre-column under diluted condition by dilution line. After elution of proteins in the serum, the analytes were backflushed onto an ODS analytical column using a six-port column-switching device. The influence of the composition of the mobile phase, for instance, organic modifer, ionic strength, pH, dilution times and the rotation time of the switching valve have been investigated using bisphenol A (BPA) and 4-octyphenol (4-OP) as analytes. The evaluations for peak responses and sensitivity were conducted by MS, and proteins were removed by RAM-column with DAD monitoring at 280 nm. The peak shape was improved by adding a dilution line, especially in the case of large volume injection (LVI), which increased the sensitivity of the analysis. The selective and sensitive quantification of BPA and 4-OP in serum sample could be finished within 25 min. The method had linearity in the range 0.1-500 ng/mL with a limit of quantification for BPA and 4-OP of 0.1 and 0.5 ng/mL, respectively. The recoveries were in the range of 80-101% with less than 9.0% RSDs. This on-line LC-MS method demonstrates potential application to evaluating the exposure and risk of BPA and 4-OP in human. (c) 2006 Elsevier B.V. All rights reserved.
WOS记录号WOS:000241772800018
源URL[http://ir.rcees.ac.cn/handle/311016/22833]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
推荐引用方式
GB/T 7714
Liu, Min,Hashi, Yuki,Pan, Fengyun,et al. Automated on-line liquid chromatography-photodiode array-mass spectrometr method with dilution line for the determination of bisphenol A and 4-octylphenol in serum[J]. JOURNAL OF CHROMATOGRAPHY A,2006,1133(2015-01-02):142-148.
APA Liu, Min,Hashi, Yuki,Pan, Fengyun,Yao, Jianguo,Song, Guanqun,&Lin, Jin-Ming.(2006).Automated on-line liquid chromatography-photodiode array-mass spectrometr method with dilution line for the determination of bisphenol A and 4-octylphenol in serum.JOURNAL OF CHROMATOGRAPHY A,1133(2015-01-02),142-148.
MLA Liu, Min,et al."Automated on-line liquid chromatography-photodiode array-mass spectrometr method with dilution line for the determination of bisphenol A and 4-octylphenol in serum".JOURNAL OF CHROMATOGRAPHY A 1133.2015-01-02(2006):142-148.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。