Solid-phase microextraction coupled with high performance liquid chromatography-fluorimetric detection for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in environmental water samples
文献类型:期刊论文
作者 | Cai, YQ; Jiang, GB; Liu, JF; Liang, X; Yao, ZW; Liu, JM; Liu, JY; Zhou, QX |
刊名 | ANALYTICAL LETTERS
![]() |
出版日期 | 2004 |
卷号 | 37期号:4页码:739-753 |
关键词 | solid-phase microextraction HPLC bisphenol A 4-n-nonylphenol 4-tert-octylphenol |
英文摘要 | Solid-phase microextraction (SPME) coupled to high performance liquid chromatography and fluorimetric detection has been-developed for the analysis of three endocrine disruptors: bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol. Several kinds of commercially available coating fibers were evaluated for their extraction efficiency to the target analytes and the carbowax/templated resin (CW/TPR) coating fiber was found to be the best one. The parameters affecting the extraction efficiency, such as absorption time, extraction temperature, pH values of the sample solutions, agitating rate, salting-out effect, desorption mode, composition of the desorption eluent, and the flow rate of mobile phase at the desorption stage, were investigated and optimized. The chromatographic conditions were also examined. The developed method has been used to determine bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol in several spiked natural water samples and good recovery results (93.9-108.2%) were obtained. Detection limits of 0.43, 0.16, and 0.29 ngmL(-1) for bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol, respectively, were achieved under the optimized conditions. |
研究领域[WOS] | Chemistry |
WOS记录号 | WOS:000220721100013 |
源URL | [http://ir.rcees.ac.cn/handle/311016/23482] ![]() |
专题 | 生态环境研究中心_环境化学与生态毒理学国家重点实验室 |
推荐引用方式 GB/T 7714 | Cai, YQ,Jiang, GB,Liu, JF,et al. Solid-phase microextraction coupled with high performance liquid chromatography-fluorimetric detection for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in environmental water samples[J]. ANALYTICAL LETTERS,2004,37(4):739-753. |
APA | Cai, YQ.,Jiang, GB.,Liu, JF.,Liang, X.,Yao, ZW.,...&Zhou, QX.(2004).Solid-phase microextraction coupled with high performance liquid chromatography-fluorimetric detection for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in environmental water samples.ANALYTICAL LETTERS,37(4),739-753. |
MLA | Cai, YQ,et al."Solid-phase microextraction coupled with high performance liquid chromatography-fluorimetric detection for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in environmental water samples".ANALYTICAL LETTERS 37.4(2004):739-753. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。