中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Evaluation of an on-line coupled continuous flow liquid membrane extraction and precolumn system as trace enrichment technique by liquid chromatographic determination of bisphenol A

文献类型:期刊论文

作者Liu, JF; Liang, X; Jiang, GB; Cai, YQ; Zhou, QX; Liu, GG
刊名TALANTA
出版日期2003
卷号60期号:6页码:1155-1161
关键词on-line enrichment continuous flow liquid membrane extraction precolumn bisphenol A water samples
英文摘要An on-line coupled continuous flow liquid membrane extraction (CFLME) and C-18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 mul of 1 mol l(-1) NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C-18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C-18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 mug l(-1) (S/N = 3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C-18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples. (C) 2003 Elsevier B.V. All rights reserved.
研究领域[WOS]Chemistry
WOS记录号WOS:000185041200008
源URL[http://ir.rcees.ac.cn/handle/311016/23684]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
推荐引用方式
GB/T 7714
Liu, JF,Liang, X,Jiang, GB,et al. Evaluation of an on-line coupled continuous flow liquid membrane extraction and precolumn system as trace enrichment technique by liquid chromatographic determination of bisphenol A[J]. TALANTA,2003,60(6):1155-1161.
APA Liu, JF,Liang, X,Jiang, GB,Cai, YQ,Zhou, QX,&Liu, GG.(2003).Evaluation of an on-line coupled continuous flow liquid membrane extraction and precolumn system as trace enrichment technique by liquid chromatographic determination of bisphenol A.TALANTA,60(6),1155-1161.
MLA Liu, JF,et al."Evaluation of an on-line coupled continuous flow liquid membrane extraction and precolumn system as trace enrichment technique by liquid chromatographic determination of bisphenol A".TALANTA 60.6(2003):1155-1161.

入库方式: OAI收割

来源:生态环境研究中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。