Some factors affecting separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection
文献类型:期刊论文
作者 | Yu, H; Ding, YS; Mou, SF |
刊名 | JOURNAL OF CHROMATOGRAPHY A
![]() |
出版日期 | 2003 |
卷号 | 997期号:1页码:145-153 |
关键词 | mobile phase composition temperature effects detection integrated pulsed amperometric detection electrochemical detection amino acids LC |
英文摘要 | Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When sodium acetate eluent concentration is changed, the selectivity variations between strongly retained amino acids containing two carboxyl groups and containing only one carboxyl group are obviously different. Significant but slight selectivity changes in weakly retained amino acids can be achieved through changing the column temperature. Sodium hydroxide and sodium acetate eluent concentration affect the detection of amino acids. Detection sensitivity of amino acids can be improved by increasing the concentration of sodium hydroxide and sodium acetate in a certain concentration range. The detections of amino acids at two different detection waveforms were compared. The hydroxyl amino acids can be selectively detected by choosing a modified detection waveform. The optimized gradient elution condition and column temperature for analyzing 19 amino acids were obtained. The time for the gradient elution program was 60 min. The column temperature was 35degreesC. Under the optimized conditions, detection limits for 19 amino acids were 0.15-4.52 pmol. The calibration graphs of peak area for all the analytes were linear for about three orders of magnitude. The RSDs (n = 5) of peak area were 0.6-5.6%. The determination of trace amino acid impurities in valine product is shown as an application example. (C) 2003 Elsevier Science B.V. All rights reserved. |
研究领域[WOS] | Biochemistry & Molecular Biology ; Chemistry |
公开日期 | 2015-12-24 |
源URL | [http://ir.rcees.ac.cn/handle/311016/23722] ![]() |
专题 | 生态环境研究中心_环境化学与生态毒理学国家重点实验室 |
推荐引用方式 GB/T 7714 | Yu, H,Ding, YS,Mou, SF. Some factors affecting separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection[J]. JOURNAL OF CHROMATOGRAPHY A,2003,997(1):145-153. |
APA | Yu, H,Ding, YS,&Mou, SF.(2003).Some factors affecting separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection.JOURNAL OF CHROMATOGRAPHY A,997(1),145-153. |
MLA | Yu, H,et al."Some factors affecting separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection".JOURNAL OF CHROMATOGRAPHY A 997.1(2003):145-153. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。