中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT

文献类型:期刊论文

作者Mu, Wei1; Chen, Zhe1; Shen, Wei1; Yang, Feng2; Liang, Ying3; Dai, Ruwei1; Wu, Ning3; Tian, Jie1
刊名IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
出版日期2015-10-01
卷号62期号:10页码:2465-2479
关键词Cervical tumor segmentation Fuzzy-C-Means (FCM) improved level set method Positron-emission tomography/computed tomography (PET/CT) images
英文摘要As positron-emission tomography (PET) images have low spatial resolution and much noise, accurate image segmentation is one of the most challenging issues in tumor quantification. Tumors of the uterine cervix present a particular challenge because of urine activity in the adjacent bladder. Here, we propose and validate an automatic segmentation method adapted to cervical tumors. Our proposed methodology combined the gradient field information of both the filtered PET image and the level set function into a level set framework by constructing a new evolution equation. Furthermore, we also constructed a new hyperimage to recognize a rough tumor region using the fuzzy c-means algorithm according to the tissue specificity as defined by both PET (uptake) and computed tomography (attenuation) to provide the initial zero level set, which could make the segmentation process fully automatic. The proposed method was verified based on simulation and clinical studies. For simulation studies, seven different phantoms, representing tumors with homogenous/heterogeneous-low/high uptake patterns and different volumes, were simulated with five different noise levels. Twenty-seven cervical cancer patients at different stages were enrolled for clinical evaluation of the method. Dice similarity coefficients (DSC) and Hausdorff distance (HD) were used to evaluate the accuracy of the segmentation method, while a Bland-Altman analysis of the mean standardized uptake value (SUVmean) and metabolic tumor volume (MTV) was used to evaluate the accuracy of the quantification. Using this method, the DSCs and HDs of the homogenous and heterogeneous phantoms under clinical noise level were 93.39 +/- 1.09% and 6.02 +/- 1.09 mm, 93.59 +/- 1.63% and 8.92 +/- 2.57 mm, respectively. The DSCs and HDs in patients measured 91.80 +/- 2.46% and 7.79 +/- 2.18 mm. Through Bland-Altman analysis, the SUVmean and the MTV using our method showed high correlation with the clinical gold standard. The results of both simulation and clinical studies demonstrated the accuracy, effectiveness, and robustness of the proposed method. Further assessment of the quantitative indices indicates the feasibility of this algorithm in accurate quantitative analysis of cervical tumors in clinical practice.
WOS标题词Science & Technology ; Technology
类目[WOS]Engineering, Biomedical
研究领域[WOS]Engineering
关键词[WOS]TEXTURE ANALYSIS ; ACTIVE CONTOURS ; FDG-PET ; CANCER ; IMAGES ; VOLUME ; QUANTIFICATION ; CT ; DELINEATION ; THERAPY
收录类别SCI
语种英语
WOS记录号WOS:000361701300014
公开日期2015-12-24
源URL[http://ir.ia.ac.cn/handle/173211/9018]  
专题自动化研究所_中国科学院分子影像重点实验室
作者单位1.Chinese Acad Sci, Inst Automat, Key Lab Mol Imaging, Beijing 100190, Peoples R China
2.Beijing Jiaotong Univ, Sch Comp & Informat Technol, Beijing, Peoples R China
3.Chinese Acad Med Sci, Canc Inst & Hosp, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Mu, Wei,Chen, Zhe,Shen, Wei,et al. A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT[J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING,2015,62(10):2465-2479.
APA Mu, Wei.,Chen, Zhe.,Shen, Wei.,Yang, Feng.,Liang, Ying.,...&Tian, Jie.(2015).A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT.IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING,62(10),2465-2479.
MLA Mu, Wei,et al."A Segmentation Algorithm for Quantitative Analysis of Heterogeneous Tumors of the Cervix With F-18-FDG PET/CT".IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING 62.10(2015):2465-2479.

入库方式: OAI收割

来源:自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。