Influence of Capillarity on Nano-Liter Flowrate Measuremet with Displacemet Method
文献类型:期刊论文
作者 | Guo Q; Cheng R; Li ZH(李战华) |
刊名 | JOURNAL OF HYDRODYNAMICS
![]() |
出版日期 | 2007 |
卷号 | 19期号:5页码:594-600 |
通讯作者邮箱 | guoqiangpost@tom.com |
关键词 | nano-liter flowrate measurement Hagen-Poiseuille (HP) formula displacement method capillarity force |
ISSN号 | 1001-6058 |
产权排序 | [Guo Qiang; Cheng Rui; Silber-Li, Zhan-hua] Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100080, Peoples R China; [Guo Qiang] Shanghai Univ, Shanghai Inst Appl Math & Mech, Shanghai 200072, Peoples R China |
通讯作者 | Guo, Q (reprint author), Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100080, Peoples R China. |
中文摘要 | Nano-liter flowrate measurements in micro-tubes with displacement method were performed and the effect of capillarity force on the accuracy was investigated through lab experiments and theoretical analysis in this article. The experiments were conducted under the pressure drops ranging from 1 kPa to 10 kPa in a circular pipe with a diameter of 50 mu m, to give the pressure-flowrate (P-Q) relation and verify the applicability of the classical Hagen-Poiseuille (HP) formula. The experimental results showed that there existed a discrepancy between the experimental data and the theoretical values predicted by the HP formula if the capillary effect was not considered, which exceeded obviously the limit of the system error. And hence a modified formula for the relation, taking the capillary effect into account, was presented through theoretical deduction, and after the HP formula had been modified the error was proved to be less than 3%, which was permitted in comparison with the system error. It was also concluded that only by eliminating the effect of the capillary force in experiments could the original HP formula be employed to predict the pressure-flowrate relation in the Hagen-Poiseuille flow in the micro-tube. |
类目[WOS] | Mechanics |
研究领域[WOS] | Mechanics |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000208248100009 |
源URL | [http://dspace.imech.ac.cn/handle/311007/58454] ![]() |
专题 | 力学研究所_力学所知识产出(1956-2008) |
推荐引用方式 GB/T 7714 | Guo Q,Cheng R,Li ZH. Influence of Capillarity on Nano-Liter Flowrate Measuremet with Displacemet Method[J]. JOURNAL OF HYDRODYNAMICS,2007,19(5):594-600. |
APA | Guo Q,Cheng R,&李战华.(2007).Influence of Capillarity on Nano-Liter Flowrate Measuremet with Displacemet Method.JOURNAL OF HYDRODYNAMICS,19(5),594-600. |
MLA | Guo Q,et al."Influence of Capillarity on Nano-Liter Flowrate Measuremet with Displacemet Method".JOURNAL OF HYDRODYNAMICS 19.5(2007):594-600. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。