Detection of Duck Hepatitis Virus Serotype1 By Biosensor Based on Imaging Ellipsometry

文献类型:期刊论文

作者Huang CH; Li JX; Tang Y; Chen YY(陈艳艳); Jin G(靳刚)
刊名CURRENT APPLIED PHYSICS
出版日期2011
卷号11期号:3页码:353-357
通讯作者邮箱yychen2006@sinano.ac.cn ; gajin@imech.ac.cn
关键词Biosensor Imaging ellipsometry Duck hepatitis virus Detection
ISSN号1567-1739
产权排序[Huang, Chenghong; Chen, Yanyan; Jin, Gang] CAS, Suzhou Inst Nanotech & Nanobion, Suzhou 215125, Peoples R China; [Li, Jixiang; Tang, Yu] Univ Southwest, Chongqing 402460, Peoples R China; [Huang, Chenghong; Jin, Gang] CAS, Inst Biophys, Beijing 100101, Peoples R China; [Jin, Gang] CAS, Inst Mech, Key Lab Micrograv, Beijing 100190, Peoples R China; [Huang, Chenghong] Chinese Acad Sci, Grad Sch, Beijing, Peoples R China
通讯作者Jin, G (reprint author), CAS, Suzhou Inst Nanotech & Nanobion, Suzhou 215125, Peoples R China.
中文摘要A novel method for the detection of duck hepatitis virus serotype1 (DHV1) using a biosensor based on imaging ellipsometry (IE) is developed. Polyclonal antibodies against DHV1 were immobilized on silicon wafers through protein A and used to capture virus particles in sample. Signals on silicon surface were acquired directly in grayscale format on an imaging ellipsometry image. This study demonstrated that the assay is rapid and accurate for detection of duck hepatitis virus. Compared with traditional methods, this technique not only has high sensitivity as low as 8 x 10(-9.5) LD(50)/ml, but can also simultaneously perform multiple serotype identification of DHV1, DHV1-g and DHV1-s. These results suggest that this biosensor might be a practicable diagnostic tool for duck hepatitis virus detection. (C) 2010 Elsevier B.V. All rights reserved.
分类号二类
类目[WOS]Materials Science, Multidisciplinary ; Physics, Applied
研究领域[WOS]Materials Science ; Physics
关键词[WOS]VISUALIZATION
收录类别SCI ; EI
语种英语
WOS记录号WOS:000288183300017
源URL[http://dspace.imech.ac.cn/handle/311007/58588]  
专题力学研究所_国家微重力实验室
推荐引用方式
GB/T 7714
Huang CH,Li JX,Tang Y,et al. Detection of Duck Hepatitis Virus Serotype1 By Biosensor Based on Imaging Ellipsometry[J]. CURRENT APPLIED PHYSICS,2011,11(3):353-357.
APA Huang CH,Li JX,Tang Y,陈艳艳,&靳刚.(2011).Detection of Duck Hepatitis Virus Serotype1 By Biosensor Based on Imaging Ellipsometry.CURRENT APPLIED PHYSICS,11(3),353-357.
MLA Huang CH,et al."Detection of Duck Hepatitis Virus Serotype1 By Biosensor Based on Imaging Ellipsometry".CURRENT APPLIED PHYSICS 11.3(2011):353-357.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。