中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research

文献类型:期刊论文

作者Liu, HQ; Wu, XZ; Xiao, TQ
刊名MEDICAL PHYSICS
出版日期2015
卷号42期号:10页码:5595—5603
关键词ATTENUATION DUALITY CONTRAST TOMOGRAPHY FRESNEL REGION SOFT-TISSUE RETRIEVAL HOLOTOMOGRAPHY INTERFEROMETER OBJECT IMAGE
ISSN号0094-2405
通讯作者Wu, XZ (reprint author), Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35249 USA.
英文摘要Purpose: Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. Methods: A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. Results: The authors' experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors' technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. Conclusions: This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure. (C) 2015 American Association of Physicists in Medicine.
语种英语
WOS记录号WOS:000362570100003
公开日期2016-03-08
源URL[http://ir.sinap.ac.cn/handle/331007/25069]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Liu, HQ,Wu, XZ,Xiao, TQ. Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research[J]. MEDICAL PHYSICS,2015,42(10):5595—5603.
APA Liu, HQ,Wu, XZ,&Xiao, TQ.(2015).Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research.MEDICAL PHYSICS,42(10),5595—5603.
MLA Liu, HQ,et al."Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research".MEDICAL PHYSICS 42.10(2015):5595—5603.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。