中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Determination of hydroxylated polychlorinated biphenyls by offline solid-phase extraction-liquid chromatography-tandem mass spectrometry using a molecularly imprinted polymer as a sorbent for sample preconcentration

文献类型:期刊论文

作者Liang, RN; Zhao, Y; Su, Y; Qin, W
刊名TALANTA
出版日期2015-11-01
卷号144页码:115-121
关键词Dummy molecularly imprinted polymers Hydroxylated polychlorinated biphenyls Liquid chromatography mass spectrometry Solid-phase extraction
ISSN号0039-9140
产权排序[Liang, Rongning; Zhao, Yan; Qin, Wei] Chinese Acad Sci, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC, Yantai 264003, Shandong, Peoples R China; [Liang, Rongning; Zhao, Yan; Qin, Wei] YICCAS, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai 264003, Shandong, Peoples R China; [Zhao, Yan] Univ Chinese Acad Sci, Beijing 100049, Peoples R China; [Su, Yang] Yantai Univ, Sch Environm & Mat Engn, Yantai 264003, Shandong, Peoples R China
通讯作者Qin, W (reprint author), Chinese Acad Sci, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai Inst Coastal Zone Res YIC, Yantai 264003, Shandong, Peoples R China. wqin@yic.ac.cn
英文摘要Hydroxylated polychlorinated biphenyls (OH-PCBs) can be detected by liquid chromatography-mass spectrometry coupled to solid-phase extraction (SPE) using a dummy molecularly imprinted polymer (DMIP) as a sorbent. The DMIP is prepared by using an analogue of OH-PCBs (i.e., 4, 4-dihydroxybiphenyl) as a dummy template, to avoid the leakage of the target molecules. The DMIP-SPE sorbent shows good recoveries for OH-PCBs at pH 11 due to the charge-assisted hydrogen bondings between OH-PCBs and the DMIP. It has been found that the DMIP is much more effective and selective than the traditional C-18-SPE method. The sample pH, polymer dosage, elution solvent and volume have been optimized for higher recoveries. Under the optimum experimental conditions, OH-PCBs can be detected in the linear concentration range of 0.05-1.0 pM, with the detection limits ranging from 11 fM to 82 fM for 4'-OH-CB 9, 4'-OH-CB 30, 4'-OH-CB 61, 4'-OH-CB 106 and 4'-OH-CB 112. The proposed system has been successfully applied to the determination of trace OH-PCBs in spiked water samples with recoveries in the range of 89-110%. (C) 2015 Elsevier B.V. All rights reserved.
研究领域[WOS]Chemistry
关键词[WOS]OH-PCBS ; PHENOLIC-COMPOUNDS ; HO-PCBS ; RECOGNITION ; METABOLITES ; BLOOD ; DEGRADATION ; WATER
收录类别SCI
语种英语
WOS记录号WOS:000363346200017
源URL[http://ir.yic.ac.cn/handle/133337/9476]  
专题烟台海岸带研究所_中科院海岸带环境过程与生态修复重点实验室
推荐引用方式
GB/T 7714
Liang, RN,Zhao, Y,Su, Y,et al. Determination of hydroxylated polychlorinated biphenyls by offline solid-phase extraction-liquid chromatography-tandem mass spectrometry using a molecularly imprinted polymer as a sorbent for sample preconcentration[J]. TALANTA,2015,144:115-121.
APA Liang, RN,Zhao, Y,Su, Y,&Qin, W.(2015).Determination of hydroxylated polychlorinated biphenyls by offline solid-phase extraction-liquid chromatography-tandem mass spectrometry using a molecularly imprinted polymer as a sorbent for sample preconcentration.TALANTA,144,115-121.
MLA Liang, RN,et al."Determination of hydroxylated polychlorinated biphenyls by offline solid-phase extraction-liquid chromatography-tandem mass spectrometry using a molecularly imprinted polymer as a sorbent for sample preconcentration".TALANTA 144(2015):115-121.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。