A new method of testing space-based high-energy electron detectors with radioactive electron sources
文献类型:期刊论文
作者 | Zhang, S.Y.; Shen, G.H.; Sun, Y.; Zhou, D.Z.; Zhang, X.X.; Li, J.W.; Huang, C.; Zhang, X.G.; Dong, Y.J.; Zhang, W.J. |
刊名 | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
![]() |
出版日期 | 2016 |
卷号 | 817页码:63-69 |
ISSN号 | 0168-9002 |
通讯作者 | Shen, G.H. (shgh@nssc.ac.cn) |
英文摘要 | Space-based electron detectors are commonly tested using radioactive β-sources which emit a continuous spectrum without spectral lines. Therefore, the tests are often to be considered only qualitative. This paper introduces a method, which results in more than a qualitative test even when using a β-source. The basic idea is to use the simulated response function of the instrument to invert the measured spectrum and compare this inverted spectrum with a reference spectrum obtained from the same source. Here we have used Geant4 to simulate the instrument response function (IRF) and a 3.5 mm thick Li-drifted Si detector to obtain the reference90Sr/90Yi source spectrum to test and verify the geometric factors of the Omni-Direction Particle Detector (ODPD) on the Tiangong-1 (TG-1) and Tiangong-2 (TG-2) spacecraft. The TG spacecraft are experimental space laboratories and prototypes of the Chinese space station. The excellent agreement between the measured and reference spectra demonstrates that this test method can be used to quantitatively assess the quality of the instrument. Due to its simplicity, the method is faster and therefore more efficient than traditional full calibrations using an electron accelerator. © 2016 Elsevier B.V. All rights reserved. |
收录类别 | EI |
语种 | 英语 |
公开日期 | 2016-04-26 |
源URL | [http://ir.nssc.ac.cn/handle/122/5329] ![]() |
专题 | 国家空间科学中心_空间环境部 |
推荐引用方式 GB/T 7714 | Zhang, S.Y.,Shen, G.H.,Sun, Y.,et al. A new method of testing space-based high-energy electron detectors with radioactive electron sources[J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2016,817:63-69. |
APA | Zhang, S.Y..,Shen, G.H..,Sun, Y..,Zhou, D.Z..,Zhang, X.X..,...&Shi, C.Y.,.(2016).A new method of testing space-based high-energy electron detectors with radioactive electron sources.Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,817,63-69. |
MLA | Zhang, S.Y.,et al."A new method of testing space-based high-energy electron detectors with radioactive electron sources".Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 817(2016):63-69. |
入库方式: OAI收割
来源:国家空间科学中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。