Analysis of surface absorbed dose in X-ray grating interferometry

文献类型:期刊论文

;
作者Wang, ZL; Wu, Z; Gao, K; Wang, DJ; Chen, H; Wang, SH; Wu, ZY;吴自玉
刊名JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA ; JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA
出版日期2014 ; 2014
卷号196期号:SI页码:85-88
关键词X-ray imaging Phase contrast Grating interferometry Surface absorbed dose X-ray imaging Phase contrast Grating interferometry Surface absorbed dose
ISSN号0368-2048
DOI10.1016/j.elspec.2014.04.010
英文摘要X-ray phase contrast imaging using grating interferometry has shown increased contrast over conventional absorption imaging, and therefore the great potential of dose reduction. The extent of the dose reduction depends on the geometry of grating interferometry, the photon energy, the properties of the sample under investigation and the utilized detector. These factors also determine the capability of grating interferometry to distinguish between different tissues with a specified statistical certainty in a single raw image. In this contribution, the required photon number for imaging and the resulting surface absorbed dose are determined in X-ray grating interferometry, using a two-component imaging object model. The presented results confirm that compared to conventional radiography, phase contrast imaging using grating interferometry indeed has the potential of dose reduction. And the extent of dose reduction is strongly dependent on the imaging conditions. Those results provide a theoretical framework for dose estimation under given imaging conditions before experimental trials, and general guidelines for optimization of grating interferometry for those dose-sensitive applications. (C) 2014 Elsevier B.V. All rights reserved.; X-ray phase contrast imaging using grating interferometry has shown increased contrast over conventional absorption imaging, and therefore the great potential of dose reduction. The extent of the dose reduction depends on the geometry of grating interferometry, the photon energy, the properties of the sample under investigation and the utilized detector. These factors also determine the capability of grating interferometry to distinguish between different tissues with a specified statistical certainty in a single raw image. In this contribution, the required photon number for imaging and the resulting surface absorbed dose are determined in X-ray grating interferometry, using a two-component imaging object model. The presented results confirm that compared to conventional radiography, phase contrast imaging using grating interferometry indeed has the potential of dose reduction. And the extent of dose reduction is strongly dependent on the imaging conditions. Those results provide a theoretical framework for dose estimation under given imaging conditions before experimental trials, and general guidelines for optimization of grating interferometry for those dose-sensitive applications. (C) 2014 Elsevier B.V. All rights reserved.
学科主题Spectroscopy ; Spectroscopy
收录类别SCI
电子版国际标准刊号1873-2526
语种英语
WOS记录号WOS:000345823400018 ; WOS:000345823400018
公开日期2016-05-03
源URL[http://ir.ihep.ac.cn/handle/311005/225077]  
专题高能物理研究所_多学科研究中心
推荐引用方式
GB/T 7714
Wang, ZL,Wu, Z,Gao, K,et al. Analysis of surface absorbed dose in X-ray grating interferometry, Analysis of surface absorbed dose in X-ray grating interferometry[J]. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA,2014, 2014,196, 196(SI):85-88, 85-88.
APA Wang, ZL.,Wu, Z.,Gao, K.,Wang, DJ.,Chen, H.,...&Wu, ZY;吴自玉.(2014).Analysis of surface absorbed dose in X-ray grating interferometry.JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA,196(SI),85-88.
MLA Wang, ZL,et al."Analysis of surface absorbed dose in X-ray grating interferometry".JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA 196.SI(2014):85-88.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。