中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Phase-contrast imaging with synchrotron hard X-ray of micro lesions of the cartilage of the femoral head in rabbits

文献类型:期刊论文

作者Sun, W; Zhang, Y; Gao, FQ; Li, ZR; Li, G; Pan, L; Li G(黎刚)
出版日期2015
卷号8期号:11页码:20086-20091
关键词Phase-contrast synchrotron femoral head cartilage
英文摘要Background: To observe micro lesions on the cartilage of the rabbit femoral head using phase-contrast imaging with synchrotron hard X-ray and to prove that this method can be useful in the study of the degeneration of cartilage. Methods: New Zealand white rabbits were used in a micro lesion model of rabbit femoral head cartilage. Bilateral femoral heads were excised from rabbits, and micro lesions were made on one side with a specially made knife with a blade 20 mu m in width. The other femur was left intact to serve as the control. Phase-contrast imaging with synchrotron hard X-ray and conventional X-ray imaging were used to observe the cartilage. Histological changes were investigated using modified Golden tri-color staining. Results: Phase-contrast imaging with synchrotron hard X-ray clearly showed the 20 mu m lesions on the cartilage on the heads of rabbit femurs. These lesions were not visible with conventional X-ray imaging. Histological observation confirmed the presence of the microscopic lesions. Conclusion: Phase-contrast imaging with synchrotron hard X-ray can detect microscopic lesions on cartilage that cannot be detected by conventional absorption-contrast X-ray. This provides an unequivocal, non-invasive alternative to histological examination in the diagnosis of joint disease. It should be considered a new tool in osteoarthritis and cartilage research.
学科主题Research & Experimental Medicine
类目[WOS]Medicine, Research & Experimental
收录类别SCI
WOS记录号WOS:000371013200032
公开日期2016-05-03
源URL[http://ir.ihep.ac.cn/handle/311005/229273]  
专题高能物理研究所_多学科研究中心
推荐引用方式
GB/T 7714
Sun, W,Zhang, Y,Gao, FQ,et al. Phase-contrast imaging with synchrotron hard X-ray of micro lesions of the cartilage of the femoral head in rabbits[J],2015,8(11):20086-20091.
APA Sun, W.,Zhang, Y.,Gao, FQ.,Li, ZR.,Li, G.,...&黎刚.(2015).Phase-contrast imaging with synchrotron hard X-ray of micro lesions of the cartilage of the femoral head in rabbits.,8(11),20086-20091.
MLA Sun, W,et al."Phase-contrast imaging with synchrotron hard X-ray of micro lesions of the cartilage of the femoral head in rabbits".8.11(2015):20086-20091.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。