A method for generating image-derived input function in quantitative F-18-FDG PET study based on the monotonicity of the input and output function curve
文献类型:期刊论文
作者 | Zhou S(周山); Zhou, S; Chen, KW; Reiman, EM; La, DM; Shan, BC; Dan BC(单保慈)![]() |
刊名 | NUCLEAR MEDICINE COMMUNICATIONS
![]() |
出版日期 | 2012 |
卷号 | 33期号:4页码:362-370 |
关键词 | F-18-fluoro-2-deoxyglucose image-derived input function positron emission tomography regional cerebral metabolic rate of glucose |
英文摘要 | Objective A method of defining the image-derived input function (IDIF) was introduced and evaluated for the quantification of the regional cerebral metabolic rate of glucose in PET studies. Methods The voxels in the brain vasculature are extracted on the basis of the different monotonicities between the input and the output function curves. Time activity curves (TACs) of such voxels are averaged to obtain the uncorrected TAC of the brain vasculature. The IDIF was obtained from the raw TAC after correcting for the partial volume and spillover effects by an empirical formula in conjunction with a single blood sample and the TAC of the brain tissue. Data from 16 patients were used to test the proposed method. The Patlak approach is used to calculate the net fluoro-2-deoxyglucose clearance with plasma-derived input function and our generated IDIF, respectively. Results The net fluoro-2-deoxyglucose clearances calculated with the IDIF generated by our approach are not only highly correlated (correlation coefficients close to 1) to, but also highly comparable (regression slopes close to 1 and intercepts close to 0) with those calculated with plasma-derived input function. Conclusion The method used in the present work is feasible and accurate. Nucl Med Commun 33:362-370 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins. |
学科主题 | Radiology, Nuclear Medicine & Medical Imaging |
收录类别 | SCI |
WOS记录号 | WOS:000301767400003 |
公开日期 | 2016-05-03 |
源URL | [http://ir.ihep.ac.cn/handle/311005/223953] ![]() |
专题 | 高能物理研究所_核技术应用研究中心 |
推荐引用方式 GB/T 7714 | Zhou S,Zhou, S,Chen, KW,et al. A method for generating image-derived input function in quantitative F-18-FDG PET study based on the monotonicity of the input and output function curve[J]. NUCLEAR MEDICINE COMMUNICATIONS,2012,33(4):362-370. |
APA | 周山.,Zhou, S.,Chen, KW.,Reiman, EM.,La, DM.,...&单保慈.(2012).A method for generating image-derived input function in quantitative F-18-FDG PET study based on the monotonicity of the input and output function curve.NUCLEAR MEDICINE COMMUNICATIONS,33(4),362-370. |
MLA | 周山,et al."A method for generating image-derived input function in quantitative F-18-FDG PET study based on the monotonicity of the input and output function curve".NUCLEAR MEDICINE COMMUNICATIONS 33.4(2012):362-370. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。