7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging
文献类型:期刊论文
作者 | Yan XQ(燕新强); Yan, XQ; Feng BT(丰宝桐)![]() ![]() ![]() |
刊名 | IEEE TRANSACTIONS ON MEDICAL IMAGING
![]() |
出版日期 | 2014 |
卷号 | 33期号:9页码:1781-1787 |
关键词 | Decoupling high field magnetic resonance imaging (MRI) human head induced current compensation or elimination (ICE) loop parallel imaging phased array radio-frequency (RF) coil |
英文摘要 | In designing large-sized volume type phased array coils for human head imaging at ultrahigh fields, e.g., 7T, minimizing electromagnetic coupling among array elements is technically challenging. A new decoupling method based on induced current compensation or elimination (ICE) for a microstrip line planar array has recently been proposed. In this study, an eight-channel transmit/receive volume array with ICE-decoupled loop elements was built and investigated to demonstrate its feasibility and robustness for human head imaging at 7T. Isolation between adjacent loop elements was better than - 25 dB with a human head load. The worst-case of the isolation between all of the elements was about - 17.5 dB. All of the MRI experiments were performed on a 7T whole-body human MR scanner. Images of the phantom and human head were acquired and g-factor maps were measured and calculated to evaluate the performance of the coil array. Compared with the conventional capacitively decoupled array, the ICE-decoupled array demonstrated improved parallel imaging ability and had a higher SNR. The experimental results indicate that the transceiver array design with ICE decoupling technique might be a promising solution to designing high performance transmit/receive coil arrays for human head imaging at ultrahigh fields. |
学科主题 | Computer Science; Engineering; Imaging Science & Photographic Technology; Radiology, Nuclear Medicine & Medical Imaging |
收录类别 | SCI |
WOS记录号 | WOS:000341773600002 |
公开日期 | 2016-05-03 |
源URL | [http://ir.ihep.ac.cn/handle/311005/225026] ![]() |
专题 | 高能物理研究所_核技术应用研究中心 |
推荐引用方式 GB/T 7714 | Yan XQ,Yan, XQ,Feng BT,et al. 7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging[J]. IEEE TRANSACTIONS ON MEDICAL IMAGING,2014,33(9):1781-1787. |
APA | 燕新强.,Yan, XQ.,丰宝桐.,Zhang, XL.,Feng, BT.,...&魏龙.(2014).7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging.IEEE TRANSACTIONS ON MEDICAL IMAGING,33(9),1781-1787. |
MLA | 燕新强,et al."7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging".IEEE TRANSACTIONS ON MEDICAL IMAGING 33.9(2014):1781-1787. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。