中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response

文献类型:期刊论文

作者Fan X(樊馨); Wang HP(王海鹏); Yuan MK(贠明凯); Sun XL(孙校丽); Cao XX(曹学香); Liu SQ(刘双全); Chai P(柴培); Li DW(李道武); Liu BD(刘宝东); Wang L(王璐)
刊名CHINESE PHYSICS B
出版日期2015
卷号24期号:1页码:18702
关键词point spread function single photon incidence system matrix positron emission tomography
通讯作者魏龙
英文摘要A point spread function (PSF) for the blurring component in positron emission tomography (PET) is studied. The PSF matrix is derived from the single photon incidence response function. A statistical iterative reconstruction (IR) method based on the system matrix containing the PSF is developed. More specifically, the gamma photon incidence upon a crystal array is simulated by Monte Carlo (MC) simulation, and then the single photon incidence response functions are calculated. Subsequently, the single photon incidence response functions are used to compute the coincidence blurring factor according to the physical process of PET coincidence detection. Through weighting the ordinary system matrix response by the coincidence blurring factors, the IR system matrix containing the PSF is finally established. By using this system matrix, the image is reconstructed by an ordered subset expectation maximization (OSEM) algorithm. The experimental results show that the proposed system matrix can substantially improve the image radial resolution, contrast, and noise property. Furthermore, the simulated single gamma-ray incidence response function depends only on the crystal configuration, so the method could be extended to any PET scanner with the same detector crystal configuration.
学科主题Physics
类目[WOS]Physics, Multidisciplinary
收录类别SCI ; EI
WOS记录号WOS:000350701400085
公开日期2016-05-03
源URL[http://ir.ihep.ac.cn/handle/311005/228281]  
专题高能物理研究所_核技术应用研究中心
推荐引用方式
GB/T 7714
Fan X,Wang HP,Yuan MK,et al. PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response[J]. CHINESE PHYSICS B,2015,24(1):18702.
APA 樊馨.,王海鹏.,贠明凯.,孙校丽.,曹学香.,...&Wei, L.(2015).PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response.CHINESE PHYSICS B,24(1),18702.
MLA 樊馨,et al."PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response".CHINESE PHYSICS B 24.1(2015):18702.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。