Coupler conditioning and high power testing of ADS Spoke cavity
文献类型:期刊论文
作者 | Chen X(陈旭); Meng FB(孟凡博); Ma Q(马强)![]() ![]() ![]() |
刊名 | CHINESE PHYSICS C
![]() |
出版日期 | 2014 |
卷号 | 38期号:2页码:27001 |
关键词 | coupler high power test Spoke cavities room temperature |
英文摘要 | Power couplers, used in China-ADS proton linac injector I, are required to transfer 6 kW RF power to the superconducting Spoke cavities. At present, first the two couplers of a coaxial design have been fabricated, which accomplished a high power test at IHEP. The test results indicated that couplers of this design are qualified to deliver 10 kW RF power in continuous travelling wave mode. This paper describes the coupler's room temperature test procedures and results and discusses the original high power test, which was terminated due to serious out-gassing and after some modifications. In the final test, the couplers smoothly exceeded the design power level. |
学科主题 | Physics |
收录类别 | SCI |
WOS记录号 | WOS:000331427100013 |
公开日期 | 2016-05-03 |
源URL | [http://ir.ihep.ac.cn/handle/311005/224910] ![]() |
专题 | 高能物理研究所_加速器中心 |
推荐引用方式 GB/T 7714 | Chen X,Meng FB,Ma Q,et al. Coupler conditioning and high power testing of ADS Spoke cavity[J]. CHINESE PHYSICS C,2014,38(2):27001. |
APA | 陈旭.,孟凡博.,马强.,黄彤明.,林海英.,...&Pan, WM.(2014).Coupler conditioning and high power testing of ADS Spoke cavity.CHINESE PHYSICS C,38(2),27001. |
MLA | 陈旭,et al."Coupler conditioning and high power testing of ADS Spoke cavity".CHINESE PHYSICS C 38.2(2014):27001. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本