CMS structural equilibrium at constant magnetic field as observed by the link alignment system

文献类型:期刊论文

作者Arce, P; Barcala, JM; Calvo, E; Ferrando, A; Josa, MI; Molinero, A; Navarrete, J; Oller, JC; Brochero, J; Calderon, A
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2012
卷号675页码:84-96
关键词CMS Alignment systems Proximity sensors Tiltmeters
英文摘要A study of the time required for the CMS detector to reach structural equilibrium once the magnetic field is ramped to its operational value of 3.8 T is presented. In addition, the results from a stability monitoring at 3.8 T over an eight-month period are given. (C) 2012 Elsevier B.V. All rights reserved.
学科主题Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
收录类别SCI
WOS记录号WOS:000302973600014
公开日期2016-05-03
源URL[http://ir.ihep.ac.cn/handle/311005/223829]  
专题高能物理研究所_粒子天体物理中心
推荐引用方式
GB/T 7714
Arce, P,Barcala, JM,Calvo, E,et al. CMS structural equilibrium at constant magnetic field as observed by the link alignment system[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2012,675:84-96.
APA Arce, P.,Barcala, JM.,Calvo, E.,Ferrando, A.,Josa, MI.,...&Jiang, C.(2012).CMS structural equilibrium at constant magnetic field as observed by the link alignment system.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,675,84-96.