中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study

文献类型:期刊论文

;
作者Singh, VP; Medhat, ME; Badiger, NM
刊名ANNALS OF NUCLEAR ENERGY ; ANNALS OF NUCLEAR ENERGY
出版日期2014 ; 2014
卷号68页码:96-100
关键词Geant4 XCOM Thermoluminescent Photon attenuation coefficients Geant4 XCOM Thermoluminescent Photon attenuation coefficients
ISSN号0306-4549
DOI10.1016/j.anucene.2014.01.011
英文摘要The mass attenuation coefficients, mu/rho of some thermoluminescent dosimetric materials with potential applications as personnel dosimeters, have been investigated using Geant4 simulation toolkit. Appreciable variations are noted for the mu/rho values by changing the photon energy and chemical compositions. The Geant4 toolkit simulation results of mu/rho are compared with experimental data wherever possible. Comparisons are also made with predictions from the XCOM program in the energy region from I keV to 100 GeV. Good agreement among Geant4 toolkit simulation, XCOM program and experimental data indicate that the Geant4 toolkit may be employed to make calculations on the mu/rho values of various dosimetric materials. The results indicate that this process can be followed to determine the interaction of photon with the several energies in different materials. (C) 2014 Elsevier Ltd. All rights reserved.; The mass attenuation coefficients, mu/rho of some thermoluminescent dosimetric materials with potential applications as personnel dosimeters, have been investigated using Geant4 simulation toolkit. Appreciable variations are noted for the mu/rho values by changing the photon energy and chemical compositions. The Geant4 toolkit simulation results of mu/rho are compared with experimental data wherever possible. Comparisons are also made with predictions from the XCOM program in the energy region from I keV to 100 GeV. Good agreement among Geant4 toolkit simulation, XCOM program and experimental data indicate that the Geant4 toolkit may be employed to make calculations on the mu/rho values of various dosimetric materials. The results indicate that this process can be followed to determine the interaction of photon with the several energies in different materials. (C) 2014 Elsevier Ltd. All rights reserved.
学科主题Nuclear Science & Technology ; Nuclear Science & Technology
收录类别SCI
语种英语
WOS记录号WOS:000333790800011 ; WOS:000333790800011
公开日期2016-05-03
源URL[http://ir.ihep.ac.cn/handle/311005/224813]  
专题高能物理研究所_实验物理中心
推荐引用方式
GB/T 7714
Singh, VP,Medhat, ME,Badiger, NM. Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study, Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study[J]. ANNALS OF NUCLEAR ENERGY, ANNALS OF NUCLEAR ENERGY,2014, 2014,68, 68:96-100, 96-100.
APA Singh, VP,Medhat, ME,&Badiger, NM.(2014).Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study.ANNALS OF NUCLEAR ENERGY,68,96-100.
MLA Singh, VP,et al."Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study".ANNALS OF NUCLEAR ENERGY 68(2014):96-100.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。