Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study
文献类型:期刊论文
; | |
作者 | Singh, VP; Medhat, ME; Badiger, NM |
刊名 | ANNALS OF NUCLEAR ENERGY
![]() ![]() |
出版日期 | 2014 ; 2014 |
卷号 | 68页码:96-100 |
关键词 | Geant4 XCOM Thermoluminescent Photon attenuation coefficients Geant4 XCOM Thermoluminescent Photon attenuation coefficients |
ISSN号 | 0306-4549 |
DOI | 10.1016/j.anucene.2014.01.011 |
英文摘要 | The mass attenuation coefficients, mu/rho of some thermoluminescent dosimetric materials with potential applications as personnel dosimeters, have been investigated using Geant4 simulation toolkit. Appreciable variations are noted for the mu/rho values by changing the photon energy and chemical compositions. The Geant4 toolkit simulation results of mu/rho are compared with experimental data wherever possible. Comparisons are also made with predictions from the XCOM program in the energy region from I keV to 100 GeV. Good agreement among Geant4 toolkit simulation, XCOM program and experimental data indicate that the Geant4 toolkit may be employed to make calculations on the mu/rho values of various dosimetric materials. The results indicate that this process can be followed to determine the interaction of photon with the several energies in different materials. (C) 2014 Elsevier Ltd. All rights reserved.; The mass attenuation coefficients, mu/rho of some thermoluminescent dosimetric materials with potential applications as personnel dosimeters, have been investigated using Geant4 simulation toolkit. Appreciable variations are noted for the mu/rho values by changing the photon energy and chemical compositions. The Geant4 toolkit simulation results of mu/rho are compared with experimental data wherever possible. Comparisons are also made with predictions from the XCOM program in the energy region from I keV to 100 GeV. Good agreement among Geant4 toolkit simulation, XCOM program and experimental data indicate that the Geant4 toolkit may be employed to make calculations on the mu/rho values of various dosimetric materials. The results indicate that this process can be followed to determine the interaction of photon with the several energies in different materials. (C) 2014 Elsevier Ltd. All rights reserved. |
学科主题 | Nuclear Science & Technology ; Nuclear Science & Technology |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000333790800011 ; WOS:000333790800011 |
公开日期 | 2016-05-03 |
源URL | [http://ir.ihep.ac.cn/handle/311005/224813] ![]() |
专题 | 高能物理研究所_实验物理中心 |
推荐引用方式 GB/T 7714 | Singh, VP,Medhat, ME,Badiger, NM. Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study, Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study[J]. ANNALS OF NUCLEAR ENERGY, ANNALS OF NUCLEAR ENERGY,2014, 2014,68, 68:96-100, 96-100. |
APA | Singh, VP,Medhat, ME,&Badiger, NM.(2014).Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study.ANNALS OF NUCLEAR ENERGY,68,96-100. |
MLA | Singh, VP,et al."Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: A comparison study".ANNALS OF NUCLEAR ENERGY 68(2014):96-100. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。