Analysis of the liquid argon purity in the ICARUS T600 TPC
文献类型:期刊论文
作者 | ICARUS Collaboration |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
出版日期 | 2004 |
卷号 | 516期号:1页码:#REF! |
关键词 | liquid argon TPC LAr purity electron drift velocity |
通讯作者 | Navas-Concha, S (reprint author), Univ Granada, Dept Fis Teor & Cosmos, Campus Fuente Nueva, E-18071 Granada, Spain. |
英文摘要 | The results reported in this paper are based on the analysis of the data recorded with the first half-module of the ICARUS T600 liquid argon Time Projection Chamber (LAr TPC), during a technical run that took place on surface in Pavia (Italy). We include results from the linearity, uniformity and calibration of the electronics, measurements on the electron drift velocity in LAr at different electric fields, as well as the LAr purity achievement of the detector. Two complementary techniques were used to measure the drift electron lifetime inside the active volume: the first, from the data of a purity monitor, gives a measurement localized in space; the second, based on the study of the signals produced by long minimum ionizing tracks crossing the detector, provides a LAr volume averaged value. Both methods yield consistent results over the whole data taking period and are compatible with an uniform LAr purity over the whole volume. The maximal drift electron lifetime value was recorded before the run stop and was about 1.8 ms. From an interpretation of the observed drift electron lifetime as a function of time, we conclude that the adopted technology would allow for drift distances exceeding 3 in. (C) 2003 Elsevier B.V. All rights reserved. |
学科主题 | Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy |
类目[WOS] | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy |
收录类别 | SCI |
WOS记录号 | WOS:000187909500007 |
公开日期 | 2016-05-03 |
源URL | [http://ir.ihep.ac.cn/handle/311005/225906] ![]() |
专题 | 高能物理研究所_实验物理中心 |
推荐引用方式 GB/T 7714 | ICARUS Collaboration. Analysis of the liquid argon purity in the ICARUS T600 TPC[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2004,516(1):#REF!. |
APA | ICARUS Collaboration.(2004).Analysis of the liquid argon purity in the ICARUS T600 TPC.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,516(1),#REF!. |
MLA | ICARUS Collaboration."Analysis of the liquid argon purity in the ICARUS T600 TPC".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 516.1(2004):#REF!. |