Modified method for diffraction aberration of one-dimensional wire chamber
文献类型:期刊论文
作者 | Wen ZW(温志文); Qi HR(祁辉荣)![]() ![]() ![]() ![]() ![]() |
刊名 | ACTA PHYSICA SINICA
![]() |
出版日期 | 2015 |
卷号 | 64期号:8页码:82901 |
关键词 | gas detector diffraction measurements synchrotron radiation correction method |
其他题名 | 一维丝室气体探测器衍射像差的修正方法研究 |
通讯作者 | 祁辉荣 |
英文摘要 | The one-dimensional position sensitive wire gaseous detector is developed for the synchrotron radiation diffraction, which consists of a single wire of gold-plated tungsten and 200 cathode strips as the readout. The induced signal is produced by the several adjacent cathode strips when X-ray is incident on anode wire with high voltage. Using the center gravity method to analyze the adjacent signals in one dimension, the primary ionization position of the X-ray can be obtained and the position resolution is 160 mu m (FWHM). In Beijing Synchrotron Radiation Facility, the diffraction test is done at the experimental station. When the X-ray irradiates the crystal sample of SiO2, the different sizes of the diffraction rings can be produced. The diffraction angles are measured to be 11.148. and 14.201., and the two-dimensional diffraction rings are reconstructed when the detector is moved and scanned with the several steps in the diffraction ring range. The diffraction aberration of one-dimensional wire chamber is very obvious. In the paper, the relevant influence factors of the detector construct are discussed. The thickness of the working gas and the width of active area window can give rise to the diffraction ring aberration. The theoretical calculation value of the diffraction aberration is larger than the position resolution value of the gaseous detector. The correction method is established based on the corresponding physical analysis, and by this method the value of the diffraction ring point is calculated. The relative aberration of diffraction position is improved by up to 7% with using the method, and the two-dimensional diffraction ring with no aberration can be reconstructed. |
学科主题 | Physics |
类目[WOS] | Physics, Multidisciplinary |
收录类别 | SCI ; EI |
WOS记录号 | WOS:000354059200013 |
公开日期 | 2016-05-03 |
源URL | [http://ir.ihep.ac.cn/handle/311005/228551] ![]() |
专题 | 高能物理研究所_实验物理中心 |
推荐引用方式 GB/T 7714 | Wen ZW,Qi HR,Dai HL,et al. Modified method for diffraction aberration of one-dimensional wire chamber[J]. ACTA PHYSICA SINICA,2015,64(8):82901. |
APA | 温志文.,祁辉荣.,代洪亮.,张余炼.,魏堃.,...&Shao, JX.(2015).Modified method for diffraction aberration of one-dimensional wire chamber.ACTA PHYSICA SINICA,64(8),82901. |
MLA | 温志文,et al."Modified method for diffraction aberration of one-dimensional wire chamber".ACTA PHYSICA SINICA 64.8(2015):82901. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。