中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
A comparative analysis of the accuracy of alternative spectral calibration methods based on TG-1 hyperspectral imager

文献类型:期刊论文

作者Zhang Ya-Qiong1; Zhang Wen-Juan1; Chen Zheng-Chao1; Zhang Bing1
刊名JOURNAL OF INFRARED AND MILLIMETER WAVES
出版日期2015
卷号34期号:3
关键词hyperspectral imager alternative calibration spectral calibration accuracy comparison
通讯作者Zhang, B (reprint author), Chinese Acad Sci, Inst Remote Sensing & Digital Earth, Key Lab Digital Earth Sci, Beijing 100094, Peoples R China.
英文摘要Based on the visible near-infrared (VNIR) data acquired by TG-1 hyperspectral imager on March 6, 2012, synchronous and non-synchronous alternative spectral calibration were assessed at the oxygen band. In order to improve the reliability of non-synchronous alternative spectral calibration result, other two images with similar imaging date were used to achieve multiple calibrations. The results show that non-synchronous alternative spectral calibration results based on three images are similar, difference is less than 0.2 nm, and standard deviation is less than 0. 11. Difference between synchronous and non-synchronous alternative spectral calibration results is less than 0. 3 nm. Compared with the TG-1 on-board spectral calibration results, the error of the two alternative spectral calibration methods is 0. 384 nm and 0.489 nm, respectively. The accuracy difference is relatively small. Non-synchronous alternative spectral calibration method can be used to achieve high-frequency spectral calibration for hyperspectral imager.
研究领域[WOS]Optics
收录类别SCI ; EI
语种中文
WOS记录号WOS:000357555600017
源URL[http://ir.ceode.ac.cn/handle/183411/38180]  
专题遥感与数字地球研究所_SCI/EI期刊论文_期刊论文
作者单位1.[Zhang Ya-Qiong
2.Zhang Wen-Juan
3.Chen Zheng-Chao
4.Zhang Bing] Chinese Acad Sci, Inst Remote Sensing & Digital Earth, Key Lab Digital Earth Sci, Beijing 100094, Peoples R China
5.[Zhang Ya-Qiong] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhang Ya-Qiong,Zhang Wen-Juan,Chen Zheng-Chao,et al. A comparative analysis of the accuracy of alternative spectral calibration methods based on TG-1 hyperspectral imager[J]. JOURNAL OF INFRARED AND MILLIMETER WAVES,2015,34(3).
APA Zhang Ya-Qiong,Zhang Wen-Juan,Chen Zheng-Chao,&Zhang Bing.(2015).A comparative analysis of the accuracy of alternative spectral calibration methods based on TG-1 hyperspectral imager.JOURNAL OF INFRARED AND MILLIMETER WAVES,34(3).
MLA Zhang Ya-Qiong,et al."A comparative analysis of the accuracy of alternative spectral calibration methods based on TG-1 hyperspectral imager".JOURNAL OF INFRARED AND MILLIMETER WAVES 34.3(2015).

入库方式: OAI收割

来源:遥感与数字地球研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。