中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Tolerance analysis for incident angle of volume phase holographic grating used in optical channel performance monitor

文献类型:会议论文

作者Xin HL ; Li F ; Cao P ; He YJ ; Chen P ; Liu YL
出版日期2004
会议名称3rd international symposium on instrumentation science and technology
会议日期aug 18-22, 2004
会议地点xian, peoples r china
关键词OCPM VPHG incident angle tolerance
页码31-35
通讯作者xin hl chinese acad sci inst semicond res & dev ctr optoelect pob 912 beijing 100083 peoples r china.
中文摘要transmission volume phase holographic grating (vphg) is adopted as spectral element in the real-time optical channel performance monitor (ocpm), which is in dire need in the dense wavelength -division-multiplexing(datdm) system. and the tolerance of incident angle, which can be fully determined by two angles: 6 and (p, is finally inferred in this paper. commonly, the default setting is that the incident plane is perpendicular to the fringes when the incident angle is mentioned. now the situation out of the vertical is discussed. by combining the theoretic analysis of vphg with its use in ocpm and changing 6 and (0 precisely in the computation and experiment, the two physical quantities which can fully specify the performance of vphg the diffraction efficiency and the resolution, are analyzed. the results show that the diffraction efficiency varies greatly with the change of 6 or (p. but from the view of the whole c-band, only the peak diffraction efficiency drifts to another wavelength. as for the resolution, it deteriorates more rapidly than diffraction efficiency with the change of (p, while more slowly with the change of theta. only if \phi\less than or equal to+/-1degrees and alpha(b) -0.5 less than or equal to theta less than or equal to alpha(b) + 0.5, the performance of the vphg would be good enough to be used in ocpm system.
英文摘要transmission volume phase holographic grating (vphg) is adopted as spectral element in the real-time optical channel performance monitor (ocpm), which is in dire need in the dense wavelength -division-multiplexing(datdm) system. and the tolerance of incident angle, which can be fully determined by two angles: 6 and (p, is finally inferred in this paper. commonly, the default setting is that the incident plane is perpendicular to the fringes when the incident angle is mentioned. now the situation out of the vertical is discussed. by combining the theoretic analysis of vphg with its use in ocpm and changing 6 and (0 precisely in the computation and experiment, the two physical quantities which can fully specify the performance of vphg the diffraction efficiency and the resolution, are analyzed. the results show that the diffraction efficiency varies greatly with the change of 6 or (p. but from the view of the whole c-band, only the peak diffraction efficiency drifts to another wavelength. as for the resolution, it deteriorates more rapidly than diffraction efficiency with the change of (p, while more slowly with the change of theta. only if \phi\less than or equal to+/-1degrees and alpha(b) -0.5 less than or equal to theta less than or equal to alpha(b) + 0.5, the performance of the vphg would be good enough to be used in ocpm system.; 于2010-10-29批量导入; made available in dspace on 2010-10-29t06:36:20z (gmt). no. of bitstreams: 1 2776.pdf: 584735 bytes, checksum: 5f7dc6921d72d77e01030373951b371b (md5) previous issue date: 2004; int comm measurements & instrumentat.; natl nat sci fdn china.; chinese soc measurement.; china instrument soc.; harbin inst technol.; instrumentat comm csm.; xian jiaotong univ.; chinese acad sci, inst semicond, res & dev ctr optoelect, beijing 100083, peoples r china
收录类别CPCI-S
会议主办者int comm measurements & instrumentat.; natl nat sci fdn china.; chinese soc measurement.; china instrument soc.; harbin inst technol.; instrumentat comm csm.; xian jiaotong univ.
会议录proceedings of the third international symposium on instrumentation science and technology, vol 3
会议录出版者harbin institute technology publishers ; 16 fuxingjie nangangqu, harbin 150006, heilongjiang, peoples r china
学科主题半导体器件
会议录出版地16 fuxingjie nangangqu, harbin 150006, heilongjiang, peoples r china
语种英语
ISBN号7-5603-2056-2
源URL[http://ir.semi.ac.cn/handle/172111/13585]  
专题半导体研究所_中国科学院半导体研究所(2009年前)
推荐引用方式
GB/T 7714
Xin HL,Li F,Cao P,et al. Tolerance analysis for incident angle of volume phase holographic grating used in optical channel performance monitor[C]. 见:3rd international symposium on instrumentation science and technology. xian, peoples r china. aug 18-22, 2004.

入库方式: OAI收割

来源:半导体研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。