A novel extraction technique based on carbon nanotubes reinforced hollow fiber solid/liquid microextraction for the measurement of piroxicam and diclofenac combined with high performance liquid chromatography
文献类型:期刊论文
作者 | Song XY(宋昕玥)1,2![]() ![]() ![]() ![]() |
刊名 | Talanta
![]() |
出版日期 | 2012 |
卷号 | 100页码:153-161 |
关键词 | Multi-walled carbon nanotubes Hollow fiber Solid/liquid phase microextraction Piroxicam Diclofenac Sol-gel technology |
ISSN号 | 0039-9140 |
通讯作者 | 陈娟 |
英文摘要 | A novel design of carbon nanotubes reinforced hollow fiber solid/liquid phase microextraction (CNTs-HF-SLPME) was developed to determine piroxicam and diclofenac in different real water samples. Functionalized multi-walled carbon nanotubes (MWCNTs) were held in the pores of hollow fiber with sol–gel technology. The pores and lumen of carbon nanotubes reinforced hollow fiber were subsequently filled with a μL volume of organic solvent (1-octanol), and then the whole assembly was used for the extraction of the target analytes in direct immersion sampling mode. The target analytes were extracted from the sample by two extractants, one of which is organic solvent placed inside the pores and lumen of hollow fiber and the other one is CNTs held in the pores of hollow fiber. After extraction, the analytes were desorbed in acetonitrile and analyzed using high performance liquid chromatography. This novel extraction mode showed more excellent extraction performance in comparison with conventional hollow fiber liquid microextraction (without adding CNTs) and carbon nanotubes reinforced hollow fiber solid microextraction (CNTs held in the pores of hollow fiber, but no organic solvents placed inside the lumen of hollow fiber) under the respective optimum conditions. This method provided 47- and 184-fold enrichment factors for piroxicam and diclofenac, respectively, good inter-fiber repeatability and batch-to-batch reproducibility. Linearity was observed in the range of 20–960 μg L−1 for piroxicam, and 10–2560 μg L−1 for diclofenac, with correlation coefficients of 0.9985 and 0.9989, respectively. The limits of detection were 4.58 μg L−1 for piroxicam and 0.40 μg L−1 for diclofenac. |
学科主题 | 分析化学与药物化学 |
收录类别 | SCI |
资助信息 | the National Nature Science Foundation of China (Nos. 21105106;21075127);Natural Science Foundation of Gansu Province (No. 1107RJZA146) |
语种 | 英语 |
WOS记录号 | WOS:000313773300021 |
源URL | [http://210.77.64.217/handle/362003/19569] ![]() |
专题 | 兰州化学物理研究所_中科院西北特色植物资源化学重点实验室/甘肃省天然药物重点实验室 |
通讯作者 | Chen J(陈娟) |
作者单位 | 1.Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, PR China 2.Graduate University of Chinese Academy of Sciences, Beijing 100039, PR China |
推荐引用方式 GB/T 7714 | Song XY,Shi YP,Chen J,et al. A novel extraction technique based on carbon nanotubes reinforced hollow fiber solid/liquid microextraction for the measurement of piroxicam and diclofenac combined with high performance liquid chromatography[J]. Talanta,2012,100:153-161. |
APA | Song XY,Shi YP,Chen J,&陈娟.(2012).A novel extraction technique based on carbon nanotubes reinforced hollow fiber solid/liquid microextraction for the measurement of piroxicam and diclofenac combined with high performance liquid chromatography.Talanta,100,153-161. |
MLA | Song XY,et al."A novel extraction technique based on carbon nanotubes reinforced hollow fiber solid/liquid microextraction for the measurement of piroxicam and diclofenac combined with high performance liquid chromatography".Talanta 100(2012):153-161. |
入库方式: OAI收割
来源:兰州化学物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。