Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas
文献类型:期刊论文
作者 | Liang, Xixi1,2; Wang, Xin1; Wang, Weiguo1; Zhou, Qinghua1,2; Chen, Chuang1; Peng, Liying1,2; Wen, Meng1,2; Qu, Tuanshuai1; Wang, Zhenxin1; Zhao, Kun1 |
刊名 | talanta
![]() |
出版日期 | 2014-04-01 |
卷号 | 121期号:1页码:215-219 |
关键词 | Black powder Ion mobility spectrometer Chlorinated hydrocarbons Modifier |
通讯作者 | 李海洋 |
英文摘要 | this paper introduces a simple method for selective and sensitive detection of black powder by adding chlorinated hydrocarbons in the drift gas instead of changing the structure of conventional ion mobility spectrometer (ims). the function of chloride modifiers was to substitute cl-(h2o)(n) for o-2- (h2o)(n) in the drift region so as to avoid the overlap between o-2(-) (h2o)(n) and sulfur ion peaks. among ch2cl2, chcl3 and ccl4, ccl4 was chosen as the modifier due to the best peak-to-peak resolution and stability towards the fluctuation of modifier concentration. with 1.4 ppm ccl4 as the modifier, the minimum detectable quantity of 0.1 ng for sulfur was achieved. moreover, this method showed the ability for detection of common explosives at sub-nanogram level, such as black powder (bp), ammonium nitrate fuel oil (anfo), 2,4,6-trinitrotoluene (tnt), and pentaerythritol tetranitrate (petn). in summary, this method requiring no configuration modification has high sensitivity and selectivity, and consumes trace amount of modifier. and these characteristics make it easy to be adopted in current deployed ims to detect black powder explosives. (c) 2014 elsevier b.v. all rights reserved. |
WOS标题词 | science & technology ; physical sciences |
学科主题 | 物理化学 |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | explosive trace detector ; mass-spectrometer ; gunshot residue ; phase |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000333791500029 |
公开日期 | 2016-05-09 |
源URL | [http://cas-ir.dicp.ac.cn/handle/321008/143963] ![]() |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100039, Peoples R China |
推荐引用方式 GB/T 7714 | Liang, Xixi,Wang, Xin,Wang, Weiguo,et al. Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas[J]. talanta,2014,121(1):215-219. |
APA | Liang, Xixi.,Wang, Xin.,Wang, Weiguo.,Zhou, Qinghua.,Chen, Chuang.,...&Li, Haiyang.(2014).Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas.talanta,121(1),215-219. |
MLA | Liang, Xixi,et al."Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas".talanta 121.1(2014):215-219. |
入库方式: OAI收割
来源:大连化学物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。