Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas

文献类型:期刊论文

作者Liang, Xixi1,2; Wang, Xin1; Wang, Weiguo1; Zhou, Qinghua1,2; Chen, Chuang1; Peng, Liying1,2; Wen, Meng1,2; Qu, Tuanshuai1; Wang, Zhenxin1; Zhao, Kun1
刊名talanta
出版日期2014-04-01
卷号121期号:1页码:215-219
关键词Black powder Ion mobility spectrometer Chlorinated hydrocarbons Modifier
通讯作者李海洋
英文摘要this paper introduces a simple method for selective and sensitive detection of black powder by adding chlorinated hydrocarbons in the drift gas instead of changing the structure of conventional ion mobility spectrometer (ims). the function of chloride modifiers was to substitute cl-(h2o)(n) for o-2- (h2o)(n) in the drift region so as to avoid the overlap between o-2(-) (h2o)(n) and sulfur ion peaks. among ch2cl2, chcl3 and ccl4, ccl4 was chosen as the modifier due to the best peak-to-peak resolution and stability towards the fluctuation of modifier concentration. with 1.4 ppm ccl4 as the modifier, the minimum detectable quantity of 0.1 ng for sulfur was achieved. moreover, this method showed the ability for detection of common explosives at sub-nanogram level, such as black powder (bp), ammonium nitrate fuel oil (anfo), 2,4,6-trinitrotoluene (tnt), and pentaerythritol tetranitrate (petn). in summary, this method requiring no configuration modification has high sensitivity and selectivity, and consumes trace amount of modifier. and these characteristics make it easy to be adopted in current deployed ims to detect black powder explosives. (c) 2014 elsevier b.v. all rights reserved.
学科主题物理化学
WOS标题词science & technology ; physical sciences
类目[WOS]chemistry, analytical
研究领域[WOS]chemistry
关键词[WOS]explosive trace detector ; mass-spectrometer ; gunshot residue ; phase
收录类别SCI
语种英语
WOS记录号WOS:000333791500029
公开日期2016-05-09
源URL[http://cas-ir.dicp.ac.cn/handle/321008/143963]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100039, Peoples R China
推荐引用方式
GB/T 7714
Liang, Xixi,Wang, Xin,Wang, Weiguo,et al. Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas[J]. talanta,2014,121(1):215-219.
APA Liang, Xixi.,Wang, Xin.,Wang, Weiguo.,Zhou, Qinghua.,Chen, Chuang.,...&Li, Haiyang.(2014).Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas.talanta,121(1),215-219.
MLA Liang, Xixi,et al."Sensitive detection of black powder by stand-alone ion mobility spectrometer with chlorinated hydrocarbon modifiers in drift gas".talanta 121.1(2014):215-219.

入库方式: OAI收割

来源:大连化学物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。