中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine

文献类型:期刊论文

作者Jia, Ming-Yan1,3; Wu, Qiong-Shui2; Li, Hui1; Zhang, Yu1; Guan, Ya-Feng1; Feng, Liang1
刊名biosensors & bioelectronics
出版日期2015-12-15
卷号74页码:1029-1037
关键词Calibration Cellphone camera Colorimetric sensor array Glucose Urine
英文摘要in this work, a novel approach that can calibrate the colors obtained with a cellphone camera was proposed for the colorimetric sensor array. the variations of ambient light conditions, imaging positions and even cellphone brands could all be compensated via taking the black and white backgrounds of the sensor array as references, thereby yielding accurate measurements. the proposed calibration approach was successfully applied to the detection of glucose in urine by a colorimetric sensor array. snapshots of the glucose sensor array by a cellphone camera were calibrated by the proposed compensation method and the urine samples at different glucose concentrations were well discriminated with no confusion after a hierarchical clustering analysis. (c) 2015 elsevier b.v. all rights reserved.
WOS标题词science & technology ; life sciences & biomedicine ; physical sciences
类目[WOS]biophysics ; biotechnology & applied microbiology ; chemistry, analytical ; electrochemistry ; nanoscience & nanotechnology
研究领域[WOS]biophysics ; biotechnology & applied microbiology ; chemistry ; electrochemistry ; science & technology - other topics
关键词[WOS]microfluidic devices ; optoelectronic nose ; quantum dots ; smartphone ; discrimination ; diagnostics ; oxidase
收录类别SCI
语种英语
WOS记录号WOS:000360772800139
公开日期2016-05-09
源URL[http://cas-ir.dicp.ac.cn/handle/321008/146533]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
2.Wuhan Univ, Elect Informat Sch, Wuhan 430072, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Jia, Ming-Yan,Wu, Qiong-Shui,Li, Hui,et al. The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine[J]. biosensors & bioelectronics,2015,74:1029-1037.
APA Jia, Ming-Yan,Wu, Qiong-Shui,Li, Hui,Zhang, Yu,Guan, Ya-Feng,&Feng, Liang.(2015).The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine.biosensors & bioelectronics,74,1029-1037.
MLA Jia, Ming-Yan,et al."The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine".biosensors & bioelectronics 74(2015):1029-1037.

入库方式: OAI收割

来源:大连化学物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。