Suspected-target pesticide screening using gas chromatography-quadrupole time-of-flight mass spectrometry with high resolution deconvolution and retention index/mass spectrum library

文献类型:期刊论文

作者Zhang F(张芳)1; Wang HY(王昊阳)1; Zhang L(张立)1; Zhang J(张菁)1; Fan RJ(范若静)1; Yu CT(余翀天)1; Wang WW(王雯雯)1; Guo YL(郭寅龙)1
刊名Talanta
出版日期2014
卷号128页码:156-163
其他题名基于解卷积和保留指数/质谱数据库的GC-QTOF MS技术对可疑农残的筛查
通讯作者郭寅龙
英文摘要A strategy for suspected-target screening of pesticide residues in complicated matrices was exploited using gas chromatography in combination with hybrid quadrupole time-of-flight mass spectrometry (GC-QTOF MS). The screening workflow followed three key steps of, initial detection, preliminary identification, and final confirmation. The initial detection of components in a matrix was done by a high resolution mass spectrum deconvolution; the preliminary identification of suspected pesticides was based on a special retention index/mass spectrum (RI/MS) library that contained both the first-stage mass spectra (MS1 spectra) and retention indices; and the final confirmation was accomplished by accurate mass measurements of representative ions with their response ratios from the MS1 spectra or representative product ions from the second-stage mass spectra (MS2 spectra). To evaluate the applicability of the workflow in real samples, three matrices of apple, spinach, and scallion, each spiked with 165 test pesticides in a set of concentrations, were selected as the models. The results showed that the use of high-resolution TOF enabled effective extractions of spectra from noisy chromatograms, which was based on a narrow mass window (5 mDa) and suspected-target compounds identified by the similarity match of deconvoluted full mass spectra and filtering of linear RIs. On average, over 74% of pesticides at 50 ng/mL could be identified using deconvolution and the RI/MS library. Over 80% of pesticides at 5 ng/mL or lower concentrations could be confirmed in each matrix using at least two representative ions with their response ratios from the MS1 spectra. In addition, the application of product ion spectra was capable of confirming suspected pesticides with specificity for some pesticides in complicated matrices. In conclusion, GC-QTOF MS combined with the RI/MS library seems to be one of the most efficient tools for the analysis of suspected-target pesticide residues in complicated matrices. (C) 2014 Elsevier B.V. All rights reserved.
学科主题分析化学
收录类别SCI
原文出处http://dx.doi.org/10.1016/j.talanta.2014.04.068
语种英语
公开日期2016-05-24
源URL[http://ir.sioc.ac.cn/handle/331003/38584]  
专题上海有机化学研究所_分析化学研究室
作者单位1.中科院上海有机化学研究所
2.安捷伦科技(中国)有限公司
推荐引用方式
GB/T 7714
Zhang F,Wang HY,Zhang L,et al. Suspected-target pesticide screening using gas chromatography-quadrupole time-of-flight mass spectrometry with high resolution deconvolution and retention index/mass spectrum library[J]. Talanta,2014,128:156-163.
APA 张芳.,王昊阳.,张立.,张菁.,范若静.,...&郭寅龙.(2014).Suspected-target pesticide screening using gas chromatography-quadrupole time-of-flight mass spectrometry with high resolution deconvolution and retention index/mass spectrum library.Talanta,128,156-163.
MLA 张芳,et al."Suspected-target pesticide screening using gas chromatography-quadrupole time-of-flight mass spectrometry with high resolution deconvolution and retention index/mass spectrum library".Talanta 128(2014):156-163.

入库方式: OAI收割

来源:上海有机化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。