平行平板角位移干涉测量仪的优化设计

文献类型:期刊论文

;
作者郑德锋 ; 王向朝
刊名中国激光
出版日期2007
卷号34期号:3页码:422
关键词激光技术 laser technique 优化设计 optimum design 误差分析 error analysis 角位移 angular displacement
ISSN号0258-7025
其他题名Optimum Design of Parallel Plate Interferometer for Angular Displacement Measurement
中文摘要提出一种可提高平行平板角位移干涉测量仪测量精度的优化设计方法。对角位移干涉测量系统进行了误差分析,讨论了影响角位移测量精度的主要因素。分析了在干涉仪光路中入射到平行平板上的初始入射角度、平行平板的折射率以及厚度等参数的选取对角位移测量精度的影响。结果表明,优化选取最佳的初始入射角度以及元件参数,并在干涉光路中附加引入一平面反射镜形成光程差放大系统,可实现的角位移测量精度达10-8 rad数量级。; An optimal design method of parallel plate interferometer is proposed in order to increase the measurement accuracy of angular displacement. The main factors determining the measurement accuracy are respectively discussed based on the analyses of the measurement error of angular displacement. It is noted that the initial angle of incidence on the plane-parallel plate, the index of refraction of the plane-parallel plate and its thickness all have great influences on the measurement accuracy. The research results show that the angular displacement measurement can be realized with higher accuracy by choosing optimal initial angle and component parameters as well as using of a reflecting mirror to amplify the optical path difference.
分类号TH741.2+3;TH744.3
收录类别ei
语种中文
公开日期2009-09-18
源URL[http://ir.siom.ac.cn/handle/181231/2242]  
专题上海光学精密机械研究所_信息光学开放实验室
推荐引用方式
GB/T 7714
郑德锋,王向朝. 平行平板角位移干涉测量仪的优化设计, Optimum Design of Parallel Plate Interferometer for Angular Displacement Measurement[J]. 中国激光,2007,34(3):422, 426.
APA 郑德锋,&王向朝.(2007).平行平板角位移干涉测量仪的优化设计.中国激光,34(3),422.
MLA 郑德锋,et al."平行平板角位移干涉测量仪的优化设计".中国激光 34.3(2007):422.

入库方式: OAI收割

来源:上海光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。