中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III) and Cr(VI) in urine of chromate workers

文献类型:期刊论文

作者Wang HJ(王华建); Wang M(王萌); Ou YH(欧阳宏); Wang B(汪冰); Zhu MT(朱墨桃); Wang Y(王云); Feng WY(丰伟悦); Wang, HJ; Du, XM; Wang, M
刊名TALANTA
出版日期2010
卷号81期号:4-5页码:1856-1860
关键词Ion-pair reversed-phase HPLC ICP-MS Cr(III) Cr(VI) Occupational exposure
通讯作者[Wang, Hua-Jian ; Wang, Meng ; Hong Ou-Yang ; Wang, Bing ; Zhu, Mo-Tao ; Wang, Yun ; Feng, Wei-Yue] Chinese Acad Sci, CAS Key Lab Nucl Analyt Tech, Beijing 100049, Peoples R China ; [Wang, Hua-Jian ; Wang, Meng ; Hong Ou-Yang ; Wang, Bing ; Zhu, Mo-Tao ; Wang, Yun ; Feng, Wei-Yue] Chinese Acad Sci, CAS Key Lab Biomed Effects Nanomat & Nanosafety, Inst High Energy Phys, Beijing 100049, Peoples R China ; [Du, Xian-Mei ; Jia, Guang] Peking Univ, Dept Occupat & Environm Hlth Sci, Sch Publ Hlth, Beijing 100083, Peoples R China ; [Wang, Tian-Cheng] Peking Univ, Hosp 3, Dept Clin Lab, Beijing 100083, Peoples R China
英文摘要Urinary chromium speciation analysis can provide available information of the individual exposure levels of Cr(VI) compounds An analytical method based on ion-pair reversed-phase HPLC combined with ICP-MS to simultaneously determine Cr(III) and Cr(VI) in human urine has been developed for assessing the occupational exposure to chromate The separation conditions of the method, including the pH value, the concentrations of ion-pair reagent and methanol in the mobile phase were studied Specially, a highspeed polyetheretherketone (PEEK) column and a typical sample introduction method were employed to avoid the exogenous chromium contamination during the analysis The separation of Cr(III) and Cr(VI) could be finished within 4 min with the detection limits as low as 003 mu g L(-1) at 100 mu L injections for both of them, providing a convenient method for routine analysis of chromium species. The chromium species in urine of chromate workers were monitored using the developed method. The statistical analysis showed a significant relationship (n = 32, p < 0 01) between the urinary Cr(VI) and the individual airborne exposure levels, indicating that the urinary Cr(VI) could be used as a convenient and suitable monitor for high level Cr(VI) occupational exposure (C) 2010 Elsevier B V. All rights reserved
学科主题Chemistry
类目[WOS]Chemistry, Analytical
研究领域[WOS]Chemistry
原文出处SCI
语种英语
WOS记录号WOS:000278737100110
源URL[http://ir.ihep.ac.cn/handle/311005/239554]  
专题高能物理研究所_多学科研究中心
高能物理研究所_加速器中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Wang HJ,Wang M,Ou YH,et al. Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III) and Cr(VI) in urine of chromate workers[J]. TALANTA,2010,81(4-5):1856-1860.
APA 王华建.,王萌.,欧阳宏.,汪冰.,朱墨桃.,...&Feng, WY.(2010).Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III) and Cr(VI) in urine of chromate workers.TALANTA,81(4-5),1856-1860.
MLA 王华建,et al."Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III) and Cr(VI) in urine of chromate workers".TALANTA 81.4-5(2010):1856-1860.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。