Investigation by slow positron beam of defects in CLAM steel induced by helium and hydrogen implantation
文献类型:期刊论文
作者 | Qiu, J; Xin, Y; Ju, X; Guo, LP; Wang, BY![]() ![]() |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS
![]() |
出版日期 | 2009 |
卷号 | 267期号:18页码:3162-3165 |
关键词 | CLAM steel Ion implantation Slow positron beam |
通讯作者 | [Qiu, J. ; Xin, Y. ; Ju, X.] Univ Sci & Technol Beijing, Dept Phys, Beijing 100083, Peoples R China ; [Guo, L. P.] Wuhan Univ, Sch Phys, Accelerator Lab, Wuhan 430072, Hubei, Peoples R China ; [Wang, B. Y. ; Zhong, Y. R.] Chinese Acad Sci, Key Lab Nucl Anal Tech, Inst High Energy Phys, Beijing 100049, Peoples R China ; [Huang, Q. Y. ; Wu, Y. C.] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China |
英文摘要 | Hydrogen and helium ion beams delivering different doses are used in the ion implantation, at room temperature, of China Low Activation Martensitic (CLAM) steel and the induced defects studied by Doppler broadening of gamma-rays generated in positron annihilation. Defect profiles are analysed in terms of conventional S and W parameters, measures of relative contributions of low and high-momentum electrons in the annihilation peak, as functions of incident positron energies E up to 30 keV. The behaviours of the S-E, W-E and S-W plots under different implantation doses indicate clearly that the induced defect size has obvious variation with depth, taking values that interpolate between surface and bulk values, and depend mainly on helium ion fluences. The S-W plot indicates that two types of defects have formed after ion implantation. (C) 2009 Elsevier B.V. All rights reserved. |
学科主题 | Instruments & Instrumentation; Nuclear Science & Technology; Physics |
类目[WOS] | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Atomic, Molecular & Chemical ; Physics, Nuclear |
研究领域[WOS] | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
原文出处 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000271349500049 |
源URL | [http://ir.ihep.ac.cn/handle/311005/239876] ![]() |
专题 | 高能物理研究所_多学科研究中心 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Qiu, J,Xin, Y,Ju, X,et al. Investigation by slow positron beam of defects in CLAM steel induced by helium and hydrogen implantation[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS,2009,267(18):3162-3165. |
APA | Qiu, J.,Xin, Y.,Ju, X.,Guo, LP.,Wang, BY.,...&钟玉荣.(2009).Investigation by slow positron beam of defects in CLAM steel induced by helium and hydrogen implantation.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS,267(18),3162-3165. |
MLA | Qiu, J,et al."Investigation by slow positron beam of defects in CLAM steel induced by helium and hydrogen implantation".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS 267.18(2009):3162-3165. |
入库方式: OAI收割
来源:高能物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。