Low-dose, simple, and fast grating-based X-ray phase-contrast imaging

文献类型:期刊论文

作者Zhu PP(朱佩平); Zhang K(张凯); Wang ZL(王志立); Liu YJ(刘宜晋); Liu XS(刘小松); Wu ZY(吴自玉); Zhu, PP; Zhang, K; Wang, ZL; Liu, YJ
刊名PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA
出版日期2010
卷号107期号:31页码:13576-13581
关键词X-ray imaging differential phase contrast grating interferometer tomography
通讯作者[Liu, Yijin ; Wu, Ziyu] Univ Sci & Technol China, Hefei 230026, Peoples R China ; [Zhu, Peiping ; Zhang, Kai ; Wang, Zhili ; Liu, Yijin ; Liu, Xiaosong ; Wu, Ziyu] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China ; [McDonald, Samuel A. ; Marone, Federica ; Stampanoni, Marco] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland ; [McDonald, Samuel A.] Univ Lausanne, Sch Med, Dept Radiol, Lausanne, Switzerland ; [Stampanoni, Marco] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland ; [Stampanoni, Marco] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8092 Zurich, Switzerland
英文摘要Phase sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging and therefore new and otherwise inaccessible information. The use of gratings as optical elements in hard X-ray phase imaging overcomes some of the problems that have impaired the wider use of phase contrast in X-ray radiography and tomography. So far, to separate the phase information from other contributions detected with a grating interferometer, a phase-stepping approach has been considered, which implies the acquisition of multiple radiographic projections. Here we present an innovative, highly sensitive X-ray tomographic phase-contrast imaging approach based on grating interferometry, which extracts the phase-contrast signal without the need of phase stepping. Compared to the existing phase-stepping approach, the main advantages of this new method dubbed "reverse projection" are not only the significantly reduced delivered dose, without the degradation of the image quality, but also the much higher efficiency. The new technique sets the prerequisites for future fast and low-dose phase-contrast imaging methods, fundamental for imaging biological specimens and in vivo studies.
学科主题Science & Technology - Other Topics
类目[WOS]Multidisciplinary Sciences
研究领域[WOS]Science & Technology - Other Topics
原文出处SCI
语种英语
WOS记录号WOS:000280605900007
源URL[http://ir.ihep.ac.cn/handle/311005/240194]  
专题高能物理研究所_多学科研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Zhu PP,Zhang K,Wang ZL,et al. Low-dose, simple, and fast grating-based X-ray phase-contrast imaging[J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA,2010,107(31):13576-13581.
APA 朱佩平.,张凯.,王志立.,刘宜晋.,刘小松.,...&Stampanoni, M.(2010).Low-dose, simple, and fast grating-based X-ray phase-contrast imaging.PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA,107(31),13576-13581.
MLA 朱佩平,et al."Low-dose, simple, and fast grating-based X-ray phase-contrast imaging".PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA 107.31(2010):13576-13581.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。