Thermal analysis for the high duty cycle PIMS accelerator
文献类型:期刊论文
作者 | Liu HC(刘华昌); Peng J(彭军); Ruan YF(阮玉芳); Fu SN(傅世年); Liu, HC; Peng, J; Ruan, YF; Fu, SN |
刊名 | CHINESE PHYSICS C |
出版日期 | 2010 |
卷号 | 34期号:7页码:1005-1008 |
关键词 | PIMS high duty cycle thermal analysis water-cooling |
通讯作者 | [Liu Hua-Chang ; Peng Jun ; Ruan Yu-Fang ; Fu Shi-Nian] CAS, Inst High Energy Phys, Accelerator Ctr, Beijing 100049, Peoples R China |
英文摘要 | To develop the high power proton linear accelerator for the Accelerator Driven System (ADS) program, the preliminary design of the Pi mode accelerating structure (HMS) has been carried out. It is estimated that PIMS would heat up to 80 degrees C for low duty cycle (0.1%) without water-cooling, which is not acceptable, thus water-cooling is demanded. The structure stability for the high duty cycle or even for CW operation is crucially important for the ADS application. Therefore, thermal analysis with water-cooling for a high duty accelerator in our ADS research is performed to control the frequency shift caused by a temperature rise. |
学科主题 | Physics |
类目[WOS] | Physics, Nuclear ; Physics, Particles & Fields |
研究领域[WOS] | Physics |
原文出处 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000279462900014 |
源URL | [http://ir.ihep.ac.cn/handle/311005/238879] |
专题 | 高能物理研究所_加速器中心 高能物理研究所_核技术应用研究中心 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Liu HC,Peng J,Ruan YF,et al. Thermal analysis for the high duty cycle PIMS accelerator[J]. CHINESE PHYSICS C,2010,34(7):1005-1008. |