中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Study of EAS local muon density spectrum and the knee in the energy spectrum of primary cosmic rays

文献类型:期刊论文

作者Liu, J; Geng, QX; Yang, HT; Liu, CQ; Zhang, P; Gao, XY; Jing, CL; Zha, M; Jing, GR; Zhu, QQ
刊名HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION
出版日期2003
卷号27期号:2页码:109-112
关键词local muon density spectrum knee energy spectrum of primary cosmic rays
其他题名宇宙线大气簇射u子定点密度及原初能谱“膝”的研究
通讯作者Yunnan Univ, Inst Cosm Ray Res, Kunming 650091, Peoples R China ; Chinese Acad Sci, Inst High Energy Phys, Beijing 100039, Peoples R China ; City Univ Hong Kong, Hong Kong, Hong Kong, Peoples R China ; Hong Kong Inst, Hong Kong, Hong Kong, Peoples R China
英文摘要With the extensive air shower (EAS) array at Mt. Liang Wang (735 g.cm(2), 245degreesN, 102.9degrees E, Kunming China) it is able to measure the muon density spectrum at a fixed distance from the core of EAS in the knee region. The spectra at two different fixed core distances (25m less than or equal to core distance < 30m,30mless than or equal tocore distance < 35m) were obtained from 4.4 x 10(4) events collected in 1994 with criteria 5 x 10(4) less than or equal to size less than or equal to 1.6 x 10(7) and 10degrees less than or equal to theta less than or equal to 30degrees that show obvious kinks. Monte Carlo simulations for the EAS development and detection with same selection criteria in the array triggering and the analysis procedure have been performed in order to relate the local muon densities to primary energy. As a result, we have deduced that the average position of the knee (E-knee) is at about 1.7 x 10(15) eV and the average difference of the slopes of the primary energy spectrum before and after the knee (Deltagamma) is about 0.43. This work corroborates the first result (Ek(nee) = 5PeV, Deltagamma = 0. 3) reported by KASCADE. It authenticates reliably the existence of the knee at the primary energy spectrum by another composition of EAS - muon composition (more direct than electron composition). Based on the results obtained by two experiments, the difference of slopes of cosmic ray primary energy spectrum before and after the knee is close to 0.4 that is accepted widely,while the energy of the knee is different from the accepted 3PeV.
学科主题Physics
类目[WOS]Physics, Nuclear ; Physics, Particles & Fields
研究领域[WOS]Physics
原文出处SCI
语种英语
WOS记录号WOS:000181047100005
源URL[http://ir.ihep.ac.cn/handle/311005/236819]  
专题高能物理研究所_粒子天体物理中心
高能物理研究所_多学科研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Liu, J,Geng, QX,Yang, HT,et al. Study of EAS local muon density spectrum and the knee in the energy spectrum of primary cosmic rays[J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,2003,27(2):109-112.
APA Liu, J.,Geng, QX.,Yang, HT.,Liu, CQ.,Zhang, P.,...&朱清棋.(2003).Study of EAS local muon density spectrum and the knee in the energy spectrum of primary cosmic rays.HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,27(2),109-112.
MLA Liu, J,et al."Study of EAS local muon density spectrum and the knee in the energy spectrum of primary cosmic rays".HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION 27.2(2003):109-112.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。