Testing the absolute beam intensity of the high-energy pulsed electron beam with a double-mode readout ionization chamber

文献类型:期刊论文

作者Gou QB(苟全补); Feng CY(冯朝阳); Shi F(石峰); Liao JY(廖进元); Gou, Q; Feng, Z; Yin, S; Shi, F; Liu, J; Dong, J
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2008
卷号592期号:3页码:498-501
关键词ionization chamber double-mode readout high-energy pulsed electron beam
通讯作者[Gou, Q. ; Feng, Z. ; Yin, S. ; Shi, F. ; Liu, J. ; Dong, J. ; Liao, J.] Chinese Acad Sci, IHEP, Beijing 100049, Peoples R China ; [Yin, S.] Shandong Univ, Jinan 250100, Peoples R China ; [Liu, J. ; Dong, J.] Lanzhou Univ, Lanzhou 730000, Gansu, Peoples R China
英文摘要We constructed an ionization chamber (IQ to test the absolute intensity of the BEPC-LINAC (Beijing Electron Positron Collider-Linear Accelerator) test beam. The IC was adapted for the 1.89 GeV high-energy electron beam, with pulse time width of 1.2 ns and frequency of 25 Hz, by equipping it with a double-mode readout and choosing the optimum circuit parameters for the readout modes. The measured absolute intensity of the test beam is 7.2 x 10(9) electron/s, and is consistent with PSPICE simulations. (c) 2008 Elsevier B.V. All rights reserved.
学科主题Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
类目[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy
研究领域[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy
原文出处SCI
语种英语
WOS记录号WOS:000258252500044
源URL[http://ir.ihep.ac.cn/handle/311005/237724]  
专题高能物理研究所_粒子天体物理中心
高能物理研究所_实验物理中心
高能物理研究所_多学科研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Gou QB,Feng CY,Shi F,et al. Testing the absolute beam intensity of the high-energy pulsed electron beam with a double-mode readout ionization chamber[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2008,592(3):498-501.
APA 苟全补.,冯朝阳.,石峰.,廖进元.,Gou, Q.,...&Liao, J.(2008).Testing the absolute beam intensity of the high-energy pulsed electron beam with a double-mode readout ionization chamber.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,592(3),498-501.
MLA 苟全补,et al."Testing the absolute beam intensity of the high-energy pulsed electron beam with a double-mode readout ionization chamber".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 592.3(2008):498-501.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。