中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The beam energy measurement system for the Beijing electron-positron collider

文献类型:期刊论文

作者Abakumova, EV; Achasov, MN; Blinov, VE; Cai, X; Dong, HY; Fu, CD; Harris, FA; Kaminsky, VV; Krasnov, AA; Liu, Q
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2011
卷号659期号:1页码:21-29
关键词Compton backscattering Beam energy calibration Collider BEPC-II tau-charm factory
通讯作者[Abakumova, E. V. ; Achasov, M. N. ; Blinov, V. E. ; Kaminsky, V. V. ; Krasnov, A. A. ; Muchnoi, N. Yu. ; Nikolaev, I. B. ; Pyata, E. E. ; Shamov, A. G. ; Todyshev, K. Yu. ; Zhukov, A. A.] Russian Acad Sci, Siberian Branch, Budker Inst Nucl Phys, Novosibirsk 630090, Russia ; [Cai, X. ; Dong, H. Y. ; Fu, C. D. ; Mo, X. H. ; Qin, Q. ; Qu, H. M. ; Wang, Y. F. ; Xiao, Q. ; Xu, J. Q. ; Zhang, J. Y. ; Zhang, T. B. ; Zhang, Y. H.] Inst High Energy Phys, Beijing 100049, Peoples R China ; [Harris, F. A. ; Liu, Q. ; Olsen, S. L. ; Shen, C. P. ; Varner, G. S.] Univ Hawaii, Honolulu, HI 96822 USA
英文摘要The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 x 10(-5). The relative uncertainty of the beam's energy spread is about 6%. (C) 2011 Elsevier B.V. All rights reserved.
学科主题Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
类目[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy
研究领域[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy
原文出处SCI
语种英语
WOS记录号WOS:000297826100004
源URL[http://ir.ihep.ac.cn/handle/311005/236791]  
专题高能物理研究所_院士
高能物理研究所_实验物理中心
高能物理研究所_粒子天体物理中心
中国科学院高能物理研究所_中国散裂中子源
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Abakumova, EV,Achasov, MN,Blinov, VE,et al. The beam energy measurement system for the Beijing electron-positron collider[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2011,659(1):21-29.
APA Abakumova, EV.,Achasov, MN.,Blinov, VE.,Cai, X.,Dong, HY.,...&Zhang YH.(2011).The beam energy measurement system for the Beijing electron-positron collider.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,659(1),21-29.
MLA Abakumova, EV,et al."The beam energy measurement system for the Beijing electron-positron collider".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 659.1(2011):21-29.

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。