中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Label-free multiplex immunoassay of AFP, CEA and CA19-9 by integrated microfluidic biosensor based on imaging ellipsometry

文献类型:期刊论文

作者Huang CH; Yang QL; Song FY; Chen N; Yao B; Liao XL; Zhang ST; Chen YY; Jin G(靳刚)
刊名INTEGRATED FERROELECTRICS
出版日期2016
卷号171期号:1页码:59-69
通讯作者邮箱chhuang2007@sinano.ac.cn ; yychen2006@sinano.ac.cn ; gajin@imech.ac.cn
关键词Imaging ellipsometry immunoassay AFP CEA CA19-9
ISSN号1058-4587
产权排序[Huang, Chenghong; Yang, QingLin; Chen, Nan; Yao, Bo; Liao, Xiaoling; Zhang, ShiTong] Chongqing Univ Sci & Technol, Inst Biomat & Living Cell Imaging Technol, Chongqing, Peoples R China; [Song, Fayi] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada; [Chen, Yanyan] Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou, Peoples R China; [Jin, Gang] Chinese Acad Sci, Inst Mech, Beijing, Peoples R China
通讯作者Huang, CH (reprint author), Chongqing Univ Sci & Technol, Inst Biomat & Living Cell Imaging Technol, Chongqing, Peoples R China. ; Chen, YY (reprint author), Chinese Acad Sci, Suzhou Inst Nanotech & Nanobion, Suzhou, Peoples R China. ; Jin, G (reprint author), Chinese Acad Sci, Inst Mech, Beijing, Peoples R China.
中文摘要This study describes the development of alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA) and carbohydrate 19-9(CA19-9) multiplex immunoassay by integrated microfluidic device based on imaging ellipsometry (IMBIE). Different strategies for AFP, CEA and CA 19-9 simultaneous immunoassay on the same aldehyde-substrate were developed. Unifying the reaction steps of CA19-9 for antigen direct detection, CEA for secondary antibody (rabbit-antiCEA) addition, AFP for secondary (rabbit antiAFP) and an enhancer (goat IgG) application, and comprehensively considering the dynamic ranges and detection sensitivities, we combined these three markers into multiplex analysis in serial format.The sensitivities and dynamic ranges for CA19-9, CEA and AFP were 10.0U/mL, 1.0 ng/mL, 1.0 ng/mL and 2.0-100.0 U/mL, 0.1-64.0 ng/mL, 1.0-128.0 ng/mL, respectively. The intra-assay and inter-assay (coefficient variations) CVs of CA19-9, CEA and AFP were between 1.6-8.9% and 2.1-7.8%. The specificities tested for both cross-reaction and heterogeneous proteins of CA19-9, CEA and AFP were not more than 6.7%. Quantitative detection of 49 sera from gastric patients demonstrated that the accuracy for gastric cancer diagnosis was 83.4%. The total detection time is only 60min for an automated process. The proposed assay has the potential for practical application.
分类号Q4
类目[WOS]Engineering, Electrical & Electronic ; Physics, Applied ; Physics, Condensed Matter
研究领域[WOS]Engineering ; Physics
关键词[WOS]Imaging ellipsometry ; immunoassay ; AFP ; CEA ; CA19-9
收录类别SCI ; EI
原文出处http://dx.doi.org/10.1080/10584587.2016.1171664
语种英语
WOS记录号WOS:000378406600009
源URL[http://dspace.imech.ac.cn/handle/311007/59532]  
专题力学研究所_国家微重力实验室
推荐引用方式
GB/T 7714
Huang CH,Yang QL,Song FY,et al. Label-free multiplex immunoassay of AFP, CEA and CA19-9 by integrated microfluidic biosensor based on imaging ellipsometry[J]. INTEGRATED FERROELECTRICS,2016,171(1):59-69.
APA Huang CH.,Yang QL.,Song FY.,Chen N.,Yao B.,...&靳刚.(2016).Label-free multiplex immunoassay of AFP, CEA and CA19-9 by integrated microfluidic biosensor based on imaging ellipsometry.INTEGRATED FERROELECTRICS,171(1),59-69.
MLA Huang CH,et al."Label-free multiplex immunoassay of AFP, CEA and CA19-9 by integrated microfluidic biosensor based on imaging ellipsometry".INTEGRATED FERROELECTRICS 171.1(2016):59-69.

入库方式: OAI收割

来源:力学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。