Partial Nucleate Pool Boiling at Low Heat Flux: Preliminary Ground Test for SOBER-SJ10
文献类型:期刊论文
作者 | Wu, K![]() ![]() ![]() |
刊名 | MICROGRAVITY SCIENCE AND TECHNOLOGY
![]() |
出版日期 | 2016 |
卷号 | 28期号:2页码:165-178 |
通讯作者邮箱 | jfzhao@imech.ac.cn |
关键词 | CMB Microgravity Self-assembly Phase transition SJ-10 |
ISSN号 | 0938-0108 |
产权排序 | [Wu, Ke; Li, Zhen-Dong; Zhao, Jian-Fu; Li, Kai] Chinese Acad Sci, Inst Mech, Key Lab Micrograv CAS, Beijing 100190, Peoples R China; [Li, Hui-Xiong] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China |
通讯作者 | Zhao, JF (reprint author), Chinese Acad Sci, Inst Mech, Key Lab Micrograv CAS, Beijing 100190, Peoples R China. |
中文摘要 | Focusing on partial nucleate pool boiling at low heat flux, SOBER-SJ10, one of 27 experiments of the program SJ-10, has been proposed to study local convection and heat transfer around an isolated growing vapor bubble during nucleate pool boiling on a well characterized flat surface in microgravity. An integrated micro heater has been developed. By using a local pulse overheating method in the experimental mode of single bubble boiling, a bubble nucleus can be excited with accurate spatial and temporal positioning on the top-side of a quartz glass substrate with a thickness of 2 mm and an effective heating area of 4.5 mm in diameter, and then grows under an approximate constant heat input provided by the main heater on the back-side of the substrate. Ten thin film micro-RTDs are used for local temperature measurements on the heating surface underneath the growing bubble. Normal pool boiling experiments can also be carried out with step-by-step increase of heating voltage. A series of ground test of the flight module of SOBER-SJ10 have been conducted. Good agreement of the measured data of single phase natural convection with the common-used empirical correlation warrants reasonable confidence in the data. It is found that the values of the incipience superheat of pool boiling at different subcooling are consistent with each others, verifying that the influence of subcooling on boiling incipience can be neglected. Pool boiling curves are also obtained, which shows great influence of subcooling on heat transfer of partial nucleate pool boiling, particularly in lower heat flux. |
分类号 | 二类 |
类目[WOS] | Engineering, Aerospace ; Thermodynamics ; Mechanics |
研究领域[WOS] | Engineering ; Thermodynamics ; Mechanics |
关键词[WOS] | CMB ; Microgravity ; Self-assembly ; Phase transition ; SJ-10 |
收录类别 | SCI ; EI |
原文出处 | http://dx.doi.org/10.1007/s12217-016-9495-8 |
语种 | 英语 |
WOS记录号 | WOS:000376652000011 |
源URL | [http://dspace.imech.ac.cn/handle/311007/59563] ![]() |
专题 | 力学研究所_国家微重力实验室 |
推荐引用方式 GB/T 7714 | Wu, K,Li ZD,Zhao JF,et al. Partial Nucleate Pool Boiling at Low Heat Flux: Preliminary Ground Test for SOBER-SJ10[J]. MICROGRAVITY SCIENCE AND TECHNOLOGY,2016,28(2):165-178. |
APA | Wu, K,李震东,赵建福,Li, HX,&李凯.(2016).Partial Nucleate Pool Boiling at Low Heat Flux: Preliminary Ground Test for SOBER-SJ10.MICROGRAVITY SCIENCE AND TECHNOLOGY,28(2),165-178. |
MLA | Wu, K,et al."Partial Nucleate Pool Boiling at Low Heat Flux: Preliminary Ground Test for SOBER-SJ10".MICROGRAVITY SCIENCE AND TECHNOLOGY 28.2(2016):165-178. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。