中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Fast Determination of Flip Angle and T-1 in Hyperpolarized Gas MRI During a Single Breath-Hold

文献类型:期刊论文

作者Zhong, Jianping1,2; Ruan, Weiwei1; Han, Yeqing1; Sun, Xianping1; Ye, Chaohui1,2; Zhou, Xin1
刊名SCIENTIFIC REPORTS
出版日期2016-05-12
卷号6
英文摘要MRI of hyperpolarized media, such as Xe-129 and He-3, shows great potential for clinical applications. The optimal use of the available spin polarization requires accurate flip angle calibrations and T-1 measurements. Traditional flip angle calibration methods are time-consuming and suffer from polarization losses during T-1 relaxation. In this paper, we propose a method to simultaneously calibrate flip angles and measure T-1 in vivo during a breath-hold time of less than 4 seconds. We demonstrate the accuracy, robustness and repeatability of this method and contrast it with traditional methods. By measuring the T-1 of hyperpolarized gas, the oxygen pressure in vivo can be calibrated during the same breath hold. The results of the calibration have been applied in variable flip angle (VFA) scheme to obtain a stable steady-state transverse magnetization. Coupled with this method, the ultra-short TE (UTE) and constant VFA (CVFA) schemes are expected to give rise to new applications of hyperpolarized media.
WOS标题词Science & Technology
类目[WOS]Multidisciplinary Sciences
研究领域[WOS]Science & Technology - Other Topics
关键词[WOS]HE-3 MRI ; NOBLE-GASES ; IN-VIVO ; LUNG ; XE-129 ; RELAXATION ; NMR ; VENTILATION ; CALIBRATION ; DYNAMICS
收录类别SCI
语种英语
WOS记录号WOS:000375644800001
源URL[http://ir.wipm.ac.cn/handle/112942/9336]  
专题武汉物理与数学研究所_磁共振应用研究部
作者单位1.Chinese Acad Sci, Key Lab Magnet Resonance Biol Syst, State Key Lab Magnet Resonance & Atom & Mol Phys, Natl Ctr Magnet Resonance Wuhan,Wuhan Inst Phys &, Wuhan 430071, Peoples R China
2.Huazhong Univ Sci & Technol, Sch Phys, Wuhan 430074, Peoples R China
推荐引用方式
GB/T 7714
Zhong, Jianping,Ruan, Weiwei,Han, Yeqing,et al. Fast Determination of Flip Angle and T-1 in Hyperpolarized Gas MRI During a Single Breath-Hold[J]. SCIENTIFIC REPORTS,2016,6.
APA Zhong, Jianping,Ruan, Weiwei,Han, Yeqing,Sun, Xianping,Ye, Chaohui,&Zhou, Xin.(2016).Fast Determination of Flip Angle and T-1 in Hyperpolarized Gas MRI During a Single Breath-Hold.SCIENTIFIC REPORTS,6.
MLA Zhong, Jianping,et al."Fast Determination of Flip Angle and T-1 in Hyperpolarized Gas MRI During a Single Breath-Hold".SCIENTIFIC REPORTS 6(2016).

入库方式: OAI收割

来源:武汉物理与数学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。