Analysis and calibration of precision for point source transmittance system

文献类型:期刊论文

作者Li Zhao-Hui1,2; Zhao Jian-Ke1; Xu Liang1; Liu Feng1; Guo Yi1; Liu Kai1; Zhao Qing1,2
刊名acta physica sinica
出版日期2016-06-05
卷号65期号:11
关键词point source transmittance calibration lens double cylindrical chamber precision
ISSN号1000-3290
其他题名点源透过率测试系统精度标定与分析
产权排序1
英文摘要

owing to space optical system working for a long time outside the field of view, where there is strong background radiation, and the fact that the point source transmittance (pst) is an important evaluation indicator for stray light suppression of this optical system, the development of stray light equipment for testing pst has received more and more attention. though the development of pst testing system has been extensively studied, none of them elaborate on the calibration of the pst testing system. besides, most of the pst testing systems are at a laboratory research stage, and the calibration of neither testing stability nor accuracy is recognized. therefore, on the basis of the pst testing system established, one calibration lens is designed to calibrate the pst testing system. by comparing the measured pst values of the calibration lens with the analyzed values, the pst testing system can be evaluated. the calibration lens model is built to analyze pst values at different off-axis angles by using the ray tracing software tracepro. we consider the accuracy of modeling, and on the basis of simplifying the structure design, we measure bidirectional reflectance distribution function values of the painted surface of the calibration lens, and then estimate values of lens surface from harvey-shack model and psd theory by taking these property data into the model of simulation. ultimately pst analyzed values of calibration lens can be obtained. finally, by comparing the measured values of calibration lens, which are tested by using pst testing system, with the analyzed values, the calibration of the pst testing system is completed. in the pst testing process of calibration lens, by analyzing the data at different off-axis angles, the accuracy of repeated measurements and threshold of pst testing system can be obtained. at the same time, testing errors caused by the stability of light source, detector linearity, air scattering and structure of double cylindrical chamber are analyzed through the testing data. the data show that when double cylindrical chamber clean class is iso 7, the pst threshold of this equipment is 10(8), and the accuracy of repeated measurements is 7.9%. taking into account the detection capability, the pst threshold of this equipment is 10(-10) when environmental condition is better than iso 6.

WOS标题词science & technology ; physical sciences
类目[WOS]physics, multidisciplinary
研究领域[WOS]physics
关键词[WOS]surface
收录类别SCI ; EI ; CSCD
语种中文
WOS记录号WOS:000380364300019
源URL[http://ir.opt.ac.cn/handle/181661/28224]  
专题西安光学精密机械研究所_检测技术研究中心
作者单位1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Li Zhao-Hui,Zhao Jian-Ke,Xu Liang,et al. Analysis and calibration of precision for point source transmittance system[J]. acta physica sinica,2016,65(11).
APA Li Zhao-Hui.,Zhao Jian-Ke.,Xu Liang.,Liu Feng.,Guo Yi.,...&Zhao Qing.(2016).Analysis and calibration of precision for point source transmittance system.acta physica sinica,65(11).
MLA Li Zhao-Hui,et al."Analysis and calibration of precision for point source transmittance system".acta physica sinica 65.11(2016).

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。