中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels

文献类型:期刊论文

作者Gao, Caixia1,2; Jiang, Xiaoguang1,2; Li, Xianbin3; Li, Xiaohui1
刊名International Journal of Remote Sensing
出版日期2013
卷号34期号:9-10页码:3688-3698
ISSN号01431161
通讯作者Jiang, X. (xgjiang@aoe.ac.cn)
中文摘要Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%. © 2013 Copyright Taylor and Francis Group, LLC.
英文摘要Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%. © 2013 Copyright Taylor and Francis Group, LLC.
学科主题Image reconstruction - Infrared devices - Radiometers - Radiometry - Remote sensing - Uncertainty analysis
收录类别SCI ; EI
语种英语
WOS记录号WOS:000330301700020
源URL[http://ir.ioe.ac.cn/handle/181551/6920]  
专题光电技术研究所_科技处
作者单位1.Academy of Opto-Electronics, Chinese Academy of Sciences, Beijing, 100190, China
2.Graduate University of Chinese Academy of Sciences, Beijing, 100049, China
3.Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, China
推荐引用方式
GB/T 7714
Gao, Caixia,Jiang, Xiaoguang,Li, Xianbin,et al. The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels[J]. International Journal of Remote Sensing,2013,34(9-10):3688-3698.
APA Gao, Caixia,Jiang, Xiaoguang,Li, Xianbin,&Li, Xiaohui.(2013).The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels.International Journal of Remote Sensing,34(9-10),3688-3698.
MLA Gao, Caixia,et al."The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels".International Journal of Remote Sensing 34.9-10(2013):3688-3698.

入库方式: OAI收割

来源:光电技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。