The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels
文献类型:期刊论文
作者 | Gao, Caixia1,2; Jiang, Xiaoguang1,2; Li, Xianbin3; Li, Xiaohui1 |
刊名 | International Journal of Remote Sensing
![]() |
出版日期 | 2013 |
卷号 | 34期号:9-10页码:3688-3698 |
ISSN号 | 01431161 |
通讯作者 | Jiang, X. (xgjiang@aoe.ac.cn) |
中文摘要 | Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%. © 2013 Copyright Taylor and Francis Group, LLC. |
英文摘要 | Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%. © 2013 Copyright Taylor and Francis Group, LLC. |
学科主题 | Image reconstruction - Infrared devices - Radiometers - Radiometry - Remote sensing - Uncertainty analysis |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000330301700020 |
源URL | [http://ir.ioe.ac.cn/handle/181551/6920] ![]() |
专题 | 光电技术研究所_科技处 |
作者单位 | 1.Academy of Opto-Electronics, Chinese Academy of Sciences, Beijing, 100190, China 2.Graduate University of Chinese Academy of Sciences, Beijing, 100049, China 3.Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, 610209, China |
推荐引用方式 GB/T 7714 | Gao, Caixia,Jiang, Xiaoguang,Li, Xianbin,et al. The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels[J]. International Journal of Remote Sensing,2013,34(9-10):3688-3698. |
APA | Gao, Caixia,Jiang, Xiaoguang,Li, Xianbin,&Li, Xiaohui.(2013).The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels.International Journal of Remote Sensing,34(9-10),3688-3698. |
MLA | Gao, Caixia,et al."The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels".International Journal of Remote Sensing 34.9-10(2013):3688-3698. |
入库方式: OAI收割
来源:光电技术研究所
浏览0
下载0
收藏0