中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

文献类型:期刊论文

作者Yao, SK; Fan, JD; Zong, YB; He, Y; Zhou, GZ; Sun, ZB; Zhang, JH; Huang, QJ; Xiao, TQ; Jiang, HD
刊名APPLIED PHYSICS LETTERS
出版日期2016
卷号108期号:12页码:
关键词PHASE-CONTRAST TOMOGRAPHY MICROSCOPY RECONSTRUCTION RETRIEVAL
ISSN号0003-6951
通讯作者Jiang, HD (reprint author), Shandong Univ, State Key Lab Crystal Mat, Jinan 250100, Peoples R China.
英文摘要Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of similar to 1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science. (C) 2016 AIP Publishing LLC.
收录类别SCI
语种英语
WOS记录号WOS:000373348000045
源URL[http://ir.sinap.ac.cn/handle/331007/25718]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Yao, SK,Fan, JD,Zong, YB,et al. Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability[J]. APPLIED PHYSICS LETTERS,2016,108(12):—.
APA Yao, SK.,Fan, JD.,Zong, YB.,He, Y.,Zhou, GZ.,...&Jiang, HD.(2016).Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability.APPLIED PHYSICS LETTERS,108(12),—.
MLA Yao, SK,et al."Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability".APPLIED PHYSICS LETTERS 108.12(2016):—.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。