Focal length measurement of Microlens-array by the clarity function of digital image
文献类型:会议论文
作者 | Zhu, Xianchang; Wu, Zhu Fan; Cao, Xuedong; Wu, Shibin; Zhang, Peng; Jing, Hongwei |
出版日期 | 2012 |
会议名称 | Proceedings of SPIE: 6th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment |
会议日期 | 2012 |
卷号 | 8417 |
页码 | 84171E |
通讯作者 | Zhu, X. |
中文摘要 | In this paper, a method for the focal length measurement of Microlens-array (MLA) is introduced. The measuring setup is composed by monochromatic, condenser, collimator, MLA, microscope and CCD sensor. An experiment was performed using a MLA whose focal length is about 8 mm and a GUI based on Matlab software was developed to analyze the image gathered at the vertex and the focus by the clarity of digital image processing technology. The measuring uncertainty of this method is about 0.8% and this method introduced in this paper can finish tens of microlens array measurement at a single shot. Compared with traditional technology for MLA measuring, this method not only has a preferable precision but also super efficiency. © 2012 SPIE. |
英文摘要 | In this paper, a method for the focal length measurement of Microlens-array (MLA) is introduced. The measuring setup is composed by monochromatic, condenser, collimator, MLA, microscope and CCD sensor. An experiment was performed using a MLA whose focal length is about 8 mm and a GUI based on Matlab software was developed to analyze the image gathered at the vertex and the focus by the clarity of digital image processing technology. The measuring uncertainty of this method is about 0.8% and this method introduced in this paper can finish tens of microlens array measurement at a single shot. Compared with traditional technology for MLA measuring, this method not only has a preferable precision but also super efficiency. © 2012 SPIE. |
收录类别 | EI |
语种 | 英语 |
ISSN号 | 0277786X |
源URL | [http://ir.ioe.ac.cn/handle/181551/7916] ![]() |
专题 | 光电技术研究所_质量处(质检中心) |
作者单位 | Institute of Optics and Electronics, Chinese Academy of Science, Chengdu, Sichuan, 610209, China |
推荐引用方式 GB/T 7714 | Zhu, Xianchang,Wu, Zhu Fan,Cao, Xuedong,et al. Focal length measurement of Microlens-array by the clarity function of digital image[C]. 见:Proceedings of SPIE: 6th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment. 2012. |
入库方式: OAI收割
来源:光电技术研究所
浏览0
下载0
收藏0
其他版本