The laboratory results of a 595-unit adaptive optical system
文献类型:会议论文
作者 | Rao, Changhui1,2; Wei, Kai1,2; Zhang, Ang1,2; Zhang, Xiaojun1,2; Zhou, Luchun1,2; Bao, Hua1,2; Wang, Shengqian1,2; Ma, Xiaoyu1,2; Guo, Youming1,2; Zhang, Xuejun1,2 |
出版日期 | 2013 |
会议名称 | 3rd Conference on Adaptive Optics for Extremely Large Telescopes, AO4ELT 2013 |
会议日期 | 2013 |
中文摘要 | A 595-unit adaptive optical system is designed for the 4-meter diameter high resolution astronomical telescope. The deformable mirror adopts PZT actuators with 300mm diameter reflecting surface. A debugging system is established in laboratory and closed loop results are obtained. The scheme of the system, the design of the wavefront sensor, the wavefront processing system and the control software are described in this paper. Special influence matrix measuring methods are for the first time used on this debugging system and show better results than the classic actuator by actuator method. The system is successfully closed loop to correct the simulated static aberration. Using FWHM as the merit, the corrected PSF equals less than 1.1 times of that of the diffraction limit. A 913-unit adaptive optical system has been developed and will be closed loop in laboratory based on the experiments of this 595-unit system. |
英文摘要 | A 595-unit adaptive optical system is designed for the 4-meter diameter high resolution astronomical telescope. The deformable mirror adopts PZT actuators with 300mm diameter reflecting surface. A debugging system is established in laboratory and closed loop results are obtained. The scheme of the system, the design of the wavefront sensor, the wavefront processing system and the control software are described in this paper. Special influence matrix measuring methods are for the first time used on this debugging system and show better results than the classic actuator by actuator method. The system is successfully closed loop to correct the simulated static aberration. Using FWHM as the merit, the corrected PSF equals less than 1.1 times of that of the diffraction limit. A 913-unit adaptive optical system has been developed and will be closed loop in laboratory based on the experiments of this 595-unit system. |
收录类别 | EI |
学科主题 | Actuators - Diffraction - Optical telescopes - Program debugging - Telescopes - Wavefronts |
语种 | 英语 |
源URL | [http://ir.ioe.ac.cn/handle/181551/7803] ![]() |
专题 | 光电技术研究所_自适应光学技术研究室(八室) |
作者单位 | 1.The Laboratory on Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China 2.The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China |
推荐引用方式 GB/T 7714 | Rao, Changhui,Wei, Kai,Zhang, Ang,et al. The laboratory results of a 595-unit adaptive optical system[C]. 见:3rd Conference on Adaptive Optics for Extremely Large Telescopes, AO4ELT 2013. 2013. |
入库方式: OAI收割
来源:光电技术研究所
浏览0
下载0
收藏0
其他版本