中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Accurate calibration method for camera and projector in fringe patterns measurement system

文献类型:期刊论文

作者Chen, Rui1,2,3; Xu, Jing1,2,3; Chen, Heping4; Su, Jianhua5; Zhang, Zonghua6; Chen, Ken1,2,3
刊名APPLIED OPTICS
出版日期2016-06-01
卷号55期号:16页码:4293-4300
英文摘要The 3D measurement system based on fringe patterns is widely applied in diverse fields. The measurement accuracy is mainly determined by camera and projector calibration accuracy. In the existing methods, the system is calibrated by a dot calibration board with traditional image process algorithms. In this paper, an improved calibration method is proposed to increase camera and projector calibration accuracy simultaneously. To this end, first, a subpixel edge detection method is proposed to improve the detection accuracy of reference features for coarse calibration; second, an iterative compensation algorithm is developed to improve the detection accuracy of the reference feature centers for fine calibration. The experimental results demonstrate that the proposed calibration method can improve the calibration accuracy and measurement accuracy. (C) 2016 Optical Society of America
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Optics
研究领域[WOS]Optics
关键词[WOS]STRUCTURED-LIGHT ; SHAPE MEASUREMENT ; OPTICAL METHODS ; REAL-TIME ; INTERFEROMETRY
收录类别SCI
语种英语
WOS记录号WOS:000377050400005
源URL[http://ir.ia.ac.cn/handle/173211/12180]  
专题自动化研究所_复杂系统管理与控制国家重点实验室_机器人应用与理论组
作者单位1.Tsinghua Univ, State Key Lab Tribol, Beijing 100084, Peoples R China
2.Tsinghua Univ, Dept Mech Engn, Beijing 100084, Peoples R China
3.Beijing Key Lab Precis Ultra Precis Mfg Equipment, Beijing 100084, Peoples R China
4.SW Texas State Univ, Ingram Sch Engn, San Marcos, TX 78666 USA
5.Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
6.Hebei Univ Technol, Mech Engn, Tianjin 300130, Peoples R China
推荐引用方式
GB/T 7714
Chen, Rui,Xu, Jing,Chen, Heping,et al. Accurate calibration method for camera and projector in fringe patterns measurement system[J]. APPLIED OPTICS,2016,55(16):4293-4300.
APA Chen, Rui,Xu, Jing,Chen, Heping,Su, Jianhua,Zhang, Zonghua,&Chen, Ken.(2016).Accurate calibration method for camera and projector in fringe patterns measurement system.APPLIED OPTICS,55(16),4293-4300.
MLA Chen, Rui,et al."Accurate calibration method for camera and projector in fringe patterns measurement system".APPLIED OPTICS 55.16(2016):4293-4300.

入库方式: OAI收割

来源:自动化研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。