Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array
文献类型:期刊论文
作者 | Zhang, Y.1,2; Huang, J.1![]() ![]() |
刊名 | JOURNAL OF INSTRUMENTATION
![]() |
出版日期 | 2016-06-01 |
卷号 | 11 |
关键词 | Cherenkov detectors Photon detectors for UV, visible and IR photons (vacuum) (photomultipliers, HPDs, others) |
英文摘要 | Since 2014, a new hybrid experiment consisting of a high-energy air-shower-core array (YAC-II), a high-density air-shower array (Tibet-III) and a large underground water-Cherenkov muon-detector array (MD) has been continued by the Tibet AS gamma collaboration to measure the chemical composition of cosmic rays in the wide energy range including the "knee". In this experiment, YAC-II is used to select high energy core events induced by cosmic rays in the above energy region, while MD is used to estimate the type of nucleus of primary particles by measuring the number of muons contained in the air showers. However, the dynamic range of each MD cell is only 5 to 2000 photoelectrons (PEs) which is mainly designed for observation of high-energy celestial gamma rays. In order to obtain the primary proton, helium and iron spectra and their "knee" positions with energy up to 1016 eV, each of PMTs equipped to the MD cell is required to measure the number of photons capable of covering a wide dynamic range of 100-106 PEs according to Monte Carlo simulations. In this paper, we firstly compare the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu. If there exists no serious difference, we will then add two 8-inch-in-diameter PMTs to meet our requirements in each MD cell, which are responsible for the range of 100-10000 PEs and 2000-1000000 PEs, respectively. That is, MD cell is expected to be able to measure the number of muons over 6 orders of magnitudes. |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000379239700028 |
源URL | [http://ir.bao.ac.cn/handle/114a11/5300] ![]() |
专题 | 国家天文台_应用天文研究部 |
作者单位 | 1.Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing 100049, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 3.Chinese Acad Sci, Natl Astron Observ, Beijing 100012, Peoples R China 4.Shandong Univ, Dept Phys, Jinan 250100, Peoples R China 5.Southwest Jiaotong Univ, Inst Modern Phys, Chengdu 610031, Peoples R China 6.Tibet Univ, Dept Phys, Sch Sci, Lhasa 850000, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Y.,Huang, J.,Chen, D.,et al. Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array[J]. JOURNAL OF INSTRUMENTATION,2016,11. |
APA | Zhang, Y..,Huang, J..,Chen, D..,Zhai, L. -M..,Chen, X..,...&Zhaxiciren.(2016).Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array.JOURNAL OF INSTRUMENTATION,11. |
MLA | Zhang, Y.,et al."Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array".JOURNAL OF INSTRUMENTATION 11(2016). |
入库方式: OAI收割
来源:国家天文台
浏览0
下载0
收藏0
其他版本