中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Qualitative Verification of CE-2's Microwave Measurement: Relative Calibration Based on Brightness Temperature Model and Data Fusion

文献类型:期刊论文

作者Hu, Guo-Ping1,2; Zheng, Yong-Chun1,2,3; Xu, Ao-Ao1,2; Tang, Ze-Sheng1,2
刊名IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING
出版日期2016-03-01
卷号54期号:3页码:1598-1609
关键词Chang'E-2 (CE-2) digital elevationmodel (DEM) lunar surface microwave brightness temperature (TB) microwave measurements radiation transfer model
英文摘要The calibration quality of the Chang'E-2 (CE-2) microwave radiometer (MRM) and the accuracy of brightness temperature (TB) data should be adequately addressed. The quality of CE-2 MRM data can be demonstrated by the analysis and simulation of TB data with the microwave transfer model and by the relative comparison between the TB and other data sets. To calibrate the TB data in a relative way, we calculated the variation of TB with respect to the latitude over certain typical regions theoretically. Three types of areas in the Moon, including the old crater, the fresh crater, and the Apollo region, are chosen as examples. A detailed method incorporating the topographic effect is employed to compute the TB. The Lunar Reconnaissance Orbiter's Diviner infrared measurement is used to ensure the accuracy of the simulated physical temperature. The consistency of the TB undulation between simulations and observations along the profile of these regions verifies the reasonability of CE-2's TB data partly. Our simulation also confirms the topographic effect of sloping walls at the crater rims on the solar heat flux received per unit surface area and reproduces the TB undulation observed by CE-2. Rock abundance and topography data are used for qualitative comparison with the CE-2 TB data. General similarity between the diurnal TB difference and the altitude profile over most craters and the similarity between the diurnal TB difference and the rock abundance profile over fresh craters can prove the relative qualification of CE-2 MRM data to a certain degree.
收录类别SCI
语种英语
WOS记录号WOS:000372369400028
源URL[http://ir.bao.ac.cn/handle/114a11/5419]  
专题国家天文台_月球与深空探测研究部
作者单位1.Macau Univ Sci & Technol, Space Sci Inst, Macau, Peoples R China
2.Chinese Acad Sci, Macau Univ Sci & Technol, Lunar Planetary Sci Lab, Partner Lab,Key Lab Lunar & Deep Space Explorat, Macau, Peoples R China
3.Chinese Acad Sci, Natl Astron Observ, Key Lab Lunar & Deep Space Explorat, Beijing 100012, Peoples R China
推荐引用方式
GB/T 7714
Hu, Guo-Ping,Zheng, Yong-Chun,Xu, Ao-Ao,et al. Qualitative Verification of CE-2's Microwave Measurement: Relative Calibration Based on Brightness Temperature Model and Data Fusion[J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING,2016,54(3):1598-1609.
APA Hu, Guo-Ping,Zheng, Yong-Chun,Xu, Ao-Ao,&Tang, Ze-Sheng.(2016).Qualitative Verification of CE-2's Microwave Measurement: Relative Calibration Based on Brightness Temperature Model and Data Fusion.IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING,54(3),1598-1609.
MLA Hu, Guo-Ping,et al."Qualitative Verification of CE-2's Microwave Measurement: Relative Calibration Based on Brightness Temperature Model and Data Fusion".IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING 54.3(2016):1598-1609.

入库方式: OAI收割

来源:国家天文台

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。