Prediction of drop size in a pulsed and non-pulsed disc and doughnut solvent extraction column

文献类型:期刊论文

作者Wang, Yong1; Smith, Kathryn H.1; Mumford, Kathryn A.1; Yi, Heng1; Wang, Lina1,2; Stevens, Geoffrey W.1
刊名CHEMICAL ENGINEERING RESEARCH & DESIGN
出版日期2016-05-01
卷号109期号:MAY页码:667-674
关键词Drop size Sauter mean diameter Pulsed disc and doughnut column Weibull function Solvent extraction
ISSN号0263-8762
英文摘要Recently a number of industrial scale pulsed disc and doughnut (PDD) solvent extraction columns have been operating with no pulsation. However most of the published research studies in the literature that describe and predict the performance of PDD columns were developed for pulsing conditions. In this study the Sauter-mean drop diameter, d(32), was measured and correlated under pulsing and non-pulsing conditions using a 75 mm diameter PDD column. Under non-pulsing conditions, the results show that the d(32) slightly decreased with increasing dispersed phase velocity, while there was no noticeable change in d(32) with continuous phase velocity. Under pulsing conditions, the d(32) decreased with increasing pulsation intensity from zero. The cumulative drop size distribution in disc and doughnut columns was found to be predicted well using the Weibull function. A new unified correlation was proposed in this study to predict the experimental d(32) data of the PDD column used in this study, as well as published experimental data which was obtained using different systems and column geometries, over a wide range of pulsation rates including no pulsation. (C) 2016 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
WOS标题词Science & Technology ; Technology
类目[WOS]Engineering, Chemical
研究领域[WOS]Engineering
关键词[WOS]DISPERSION
收录类别SCI
语种英语
WOS记录号WOS:000376695200062
源URL[http://ir.ipe.ac.cn/handle/122111/20953]  
专题过程工程研究所_湿法冶金清洁生产技术国家工程实验室
作者单位1.Univ Melbourne, Particulate Fluids Proc Ctr, Dept Chem & Biomol Engn, Parkville, Vic 3010, Australia
2.Chinese Acad Sci, Inst Proc Engn, Key Lab Green Proc & Engn, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Wang, Yong,Smith, Kathryn H.,Mumford, Kathryn A.,et al. Prediction of drop size in a pulsed and non-pulsed disc and doughnut solvent extraction column[J]. CHEMICAL ENGINEERING RESEARCH & DESIGN,2016,109(MAY):667-674.
APA Wang, Yong,Smith, Kathryn H.,Mumford, Kathryn A.,Yi, Heng,Wang, Lina,&Stevens, Geoffrey W..(2016).Prediction of drop size in a pulsed and non-pulsed disc and doughnut solvent extraction column.CHEMICAL ENGINEERING RESEARCH & DESIGN,109(MAY),667-674.
MLA Wang, Yong,et al."Prediction of drop size in a pulsed and non-pulsed disc and doughnut solvent extraction column".CHEMICAL ENGINEERING RESEARCH & DESIGN 109.MAY(2016):667-674.

入库方式: OAI收割

来源:过程工程研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。