Measurements of spectral parameters for nitrous oxide near 4.56 mu m using a quantum cascade laser
文献类型:期刊论文
| 作者 | Li F(李飞) ; Ceng H(曾徽); Wang KL ; Zhang SH(张少华) ; Yu XL(余西龙)
|
| 刊名 | JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER
![]() |
| 出版日期 | 2016 |
| 卷号 | 185页码:79-85 |
| 通讯作者邮箱 | lifei@imech.ac.cn ; zenghui@imech.ac.cn ; wangkuanliang@imech.ac.cn ; shzh@imech.ac.cn ; xlyu@imech.ac.cn |
| 关键词 | Nitrous oxide Quantum cascade laser Linestrength N-2-broadening coefficient Temperature exponent |
| ISSN号 | 0022-4073 |
| 产权排序 | [Li, Fei; Zeng, Hui; Wang, Kuanliang; Zhang, Shaohua; Yu, Xilong] Chinese Acad Sci, State Key Lab High Temp Gas Dynam, Inst Mech, Beijing 100190, Peoples R China |
| 通讯作者 | Yu, XL (reprint author), Chinese Acad Sci, State Key Lab High Temp Gas Dynam, Inst Mech, Beijing 100190, Peoples R China. |
| 中文摘要 | Line strengths and nitrogen (N-2)-broadening coefficients for six nitrous oxide transitions were measured using a continuous-wave quantum cascade laser (cw-QCL) operating near 4.56 mu m. The temperature dependence of the exponent n for the N-2-broadening coefficients was determined over the range 298-800 K using a sapphire-sealed optical cell. Spectral parameters were determined by fitting absorption spectra with multi-peak Voigt profiles. The line strengths for the six transitions are 0-3% larger than those in the HITRAN 2012 database, while the N-2-broadening coefficients at the reference temperature are 2-5% smaller than the HITRAN 2012 values. (C) 2016 Elsevier Ltd. All rights reserved. |
| 分类号 | 二类 |
| 类目[WOS] | Optics ; Spectroscopy |
| 研究领域[WOS] | Optics ; Spectroscopy |
| 关键词[WOS] | Nitrous oxide ; Quantum cascade laser ; Linestrength ; N-2-broadening coefficient ; Temperature exponent |
| 收录类别 | SCI |
| 原文出处 | http://dx.doi.org/10.1016/j.jqsrt.2016.08.016 |
| 语种 | 英语 |
| WOS记录号 | WOS:000387193300009 |
| 源URL | [http://dspace.imech.ac.cn/handle/311007/59684] ![]() |
| 专题 | 力学研究所_高温气体动力学国家重点实验室 |
| 推荐引用方式 GB/T 7714 | Li F,Ceng H,Wang KL,et al. Measurements of spectral parameters for nitrous oxide near 4.56 mu m using a quantum cascade laser[J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER,2016,185:79-85. |
| APA | Li F,Ceng H,Wang KL,Zhang SH,&Yu XL.(2016).Measurements of spectral parameters for nitrous oxide near 4.56 mu m using a quantum cascade laser.JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER,185,79-85. |
| MLA | Li F,et al."Measurements of spectral parameters for nitrous oxide near 4.56 mu m using a quantum cascade laser".JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER 185(2016):79-85. |
入库方式: OAI收割
来源:力学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


