中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Solely Abluminal Drug Release From Coronary Stents Could Possibly Improve Reendothelialization

文献类型:期刊论文

作者Zhang, Haijun1,2; Deng, Wei3; Wang, Xiangfei2; Wang, Shenguo1,4; Ge, Junbo2; Toft, Egon1,5
刊名CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
出版日期2016-09-01
卷号88期号:3页码:E59-E66
关键词biodegradable polymer sirolimus drug eluting stent animal experiment coronary arteries abluminal drug elution
英文摘要Objectives: To compare a new stent with an asymmetric coating, eluting the drug to the abluminal surface, to a stent with a conventional coating eluting the drug both to the luminal and the abluminal side. Background: Stents with asymmetric coating, eluting the drug to the vessel wall (BPSES-A), could potentially give faster reendothelialization after percutaneous coronary interventions (PCI) and decrease in in-stent thrombosis and late restenosis. Methods: BPSES-A, conventional coated stents (BPSES-C), biodegradable polymer stents without drug (BPS, for control), and bare metal stents (BMS, for control) were implanted into the coronary arteries of 38 pigs (75 stents). Pigs were sacrificed after 4, 12, and 24 weeks. Quantitative coronary angiography was used to compare in-stent late lumen loss (LLL) and electron microscopy was used to reveal levels of reendothelialization. Results: The stents were all successfully implanted. LLL of BPSES-A, BPSES-C, BMS, and BPS were 0.56 +/- 0.51, 0.60 +/- 0.58, 0.89 +/- 0.43, and 1.68 +/- 0.30 mm, respectively, after 4 weeks. LLL of BPSES-A and BPSES-C were 0.63 +/- 0.53 and 0.69 +/- 0.24 mm, respectively, after 12 weeks. LLL of BPSES-A, BPSES-C, and BMS were 0.42 +/- 0.15 m, 0.56 +/- 0.28 mm, and 0.99 +/- 0.13 mm, respectively, after 24 weeks. The scaling of reendothelialization was as follows: after 4 weeks BMS> = BPS>BPSES-A>BPSES-C, after 12 weeks BPSES-A>BPSES-C, and after 24 weeks BMS>BPSES-A>BPSES-C. Reendothelialization was better in BPSES-A than BPSES-C (P<0.05). There was no correlation between LLL and reendothelialization (P=0.42). Conclusion: Asymmetric coating of coronary stents might be helpful to improve reendothelialization. (C) 2016 Wiley Periodicals, Inc.
收录类别SCI
语种英语
源URL[http://ir.iccas.ac.cn/handle/121111/35169]  
专题化学研究所_高分子物理与化学实验室
作者单位1.Aalborg Univ, Fac Med, Dept Hlth Sci & Technol, Aalborg O, Denmark
2.Fudan Univ, Shanghai Inst Cardiovasc Dis, Zhongshan Hosp, Shanghai, Peoples R China
3.Fudan Univ, Sch Publ Hlth, Key Lab Publ Hlth Safety, Minist Educ, Shanghai, Peoples R China
4.Chinese Acad Sci, Inst Chem, Beijing, Peoples R China
5.Qatar Univ, Coll Med, Biomed Res Ctr, Postbox 2716, Doha, Qatar
推荐引用方式
GB/T 7714
Zhang, Haijun,Deng, Wei,Wang, Xiangfei,et al. Solely Abluminal Drug Release From Coronary Stents Could Possibly Improve Reendothelialization[J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS,2016,88(3):E59-E66.
APA Zhang, Haijun,Deng, Wei,Wang, Xiangfei,Wang, Shenguo,Ge, Junbo,&Toft, Egon.(2016).Solely Abluminal Drug Release From Coronary Stents Could Possibly Improve Reendothelialization.CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS,88(3),E59-E66.
MLA Zhang, Haijun,et al."Solely Abluminal Drug Release From Coronary Stents Could Possibly Improve Reendothelialization".CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS 88.3(2016):E59-E66.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。