中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Magnetic field measurement by weak magnetic-sensitive Zeeman splitting

文献类型:期刊论文

作者Dong, Richang; Wei, Rong; Du, Yuanbo; Zou, Fan; Lin, Jinda; Wang, Yuzhu
刊名appl. phys. lett.
出版日期2015
卷号106期号:15页码:152402
通讯作者wei, r (reprint author), chinese acad sci, shanghai inst opt & fine mech, key lab quantum opt, shanghai 201800, peoples r china.
英文摘要we present a method for magnetic field measurement by the weak magnetic-sensitive zeeman splitting based on stimulated raman transition. the magnetic field intensity measured by our proposed method is consistent with that by the magnetic-sensitive method in the error range of 0.5%. compared with the traditional measurement, the contrast of the weak magnetic-sensitive resonance signal is improved significantly for gradient field. the dependence of the raman transitions on polarization schemes is analyzed. the cancellation of the differential light shift between the separated peaks is demonstrated by proper choice of polarization configuration. the presented method is applicable to measuring the magnetic field with large gradient, such as 2-40 mg/mm in our clock, where the traditional method is unsuitable. (c) 2015 aip publishing llc.
收录类别SCI
语种英语
版本出版稿
源URL[http://ir.siom.ac.cn/handle/181231/14023]  
专题上海光学精密机械研究所_量子光学重点实验室
作者单位1.[Dong, Richang
2.Wei, Rong
3.Du, Yuanbo
4.Zou, Fan
5.Lin, Jinda
6.Wang, Yuzhu] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Key Lab Quantum Opt, Shanghai 201800, Peoples R China
7.[Dong, Richang
8.Du, Yuanbo
9.Zou, Fan] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Dong, Richang,Wei, Rong,Du, Yuanbo,et al. Magnetic field measurement by weak magnetic-sensitive Zeeman splitting[J]. appl. phys. lett.,2015,106(15):152402.
APA Dong, Richang,Wei, Rong,Du, Yuanbo,Zou, Fan,Lin, Jinda,&Wang, Yuzhu.(2015).Magnetic field measurement by weak magnetic-sensitive Zeeman splitting.appl. phys. lett.,106(15),152402.
MLA Dong, Richang,et al."Magnetic field measurement by weak magnetic-sensitive Zeeman splitting".appl. phys. lett. 106.15(2015):152402.

入库方式: OAI收割

来源:上海光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。