计算机采样-输出实现钛宝石激光器稳频

文献类型:期刊论文

作者周蜀渝; 周善钰; 王育竹
刊名中国激光
出版日期2003
卷号30期号:1页码:9
其他题名Computer Sampling Error Singal control Output Voltage to Stabilize Frequency of the Ti: sapphire Laser
中文摘要采用计算机采样误差信号并控制输出电压的方法,实现连续输出的钛宝石激光器稳频。误差信号由偏振光谱提供,可避免由稳频后因激光功率变化所导致的剩余误差。
英文摘要It is reported using a computer sampling error signal and outputting control voltage to stabilize frequency of the Ti:sapphire laser. Using error signal offered by polarization spectroscopy can avoid error which produced by laser intensity swing.